7 Putting out of operation
7 Putting out of operation
8 Maintenance and cleaning
EN - 16
NOTICE
• When putting the system out of operation, ensure that the procedures for
switching off each of the welding system components are observed.
1 Switch off the cutting power source.
2 Close the compressed air valve.
Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of burns
The welding torches reach very high temperatures during welding.
• Allow the welding torches to cool down.
• Wear the correct protective gloves.
PSB