Specific Operating Instructions
1
2
3
6
5
4
Display (8):
8.1
8.2
8.3
8.4
8.5
8.6
Further explanation of display symbols:
Symbol delay (8.2):
When the device notices that the energy needs to be increased, the display comes on. (Vegetation etc.)
(The delay time (min. 15s) is waited for, then the device increases the energy - the symbol goes out at maximum)
Alarm symbol (8.11):
The device comes into the alarm state (a pulse is over 1000 OHM, the next pulse is below 400 OHM). (e.g. human touch)
If the increased load persists after 6 pulses, the alarm horn goes on and the pulse time becomes 3sec. extended.
After 15min. Without changing the load, the alarm mode stops, the device increases the energy and views the new fence
stand as NORMAL.
a.) Installation
Fastening holes (4) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall
with the connections at the bottom, see above picture, left part. For outside installation the device must also
be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses
(green or red). The device is ready for operation. If control lights do not flash, the power supply or power
supply line must be checked first. If no fault can be detected, the device should be tested by a specialist.
8
This energizer shall not be
used as an animal trainer
(inside a barn).
7
8.7
9
8.12
8.11
8.10
8.9
8.8
(Unit: e.g. 1kV = 1000V)
3
Switch
1= ECO-Mode
1
0 = OFF
2 = EXTREM-Mode
Connection Mains adapter
2
Art.No.: 371030
230V
Connection 12V cable
3
Art.Nr.: 269790
4
Earth connection
Reference earth (required)
Insert the earth spike separately
5
into the earth (min. 2m distance to
the device earth)
Fence loop (optional)
6
7
Fence connection
8
Display with bar graph
9
Mounting holes
Fence tension
8.1
Delay icon
8.2
Fence pulse icon
8.3
AC adapter connected
8.4
Switch mode
8.5
(ECO or EXTREME)
Earth tension
8.6
Fence loop
8.7
Battery status icon
8.8
Battery tension
8.9
8.10 Fence tension unit
Alarm icon
8.11
Sudden event in the fence
LED bar graph (optical
8.12
support fence condition)
-EN-
Version : 2021.1