Eu Declaration Of Conformity - Nibe Contura C690AG Mode D'emploi

Masquer les pouces Voir aussi pour Contura C690AG:
Table des Matières

Publicité

GB
22

EU Declaration of Conformity

Manufacturer
Address
E-Mail
Website
Telephone
THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT:
Trade name
Identification of product
THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -
THE RELEVANT UNION HARMONIZATION LEGISLATION:
DIR 2009/125/EC
REG (EU) 2015/1185
REG (EU) 2015/1186
REG (EU) 2017/1369
REG (EU) 305/2011
TECHNICAL DOCUMENTATION
Indirect heating functionality:
Direct heat output:
Energy Efficiency Index (EEI):
Test report
FUEL
Wood logs with moisture content ≤25%
Compressed wood with moisture content <12%
Other woody biomass
Non-wood biomass
Anthracite and dry steam coal
Hard coke
Low temperature coke
Bituminous coal
Lignite briquettes
Peat briquettes
Blended fossil fuel briquettes
Other fossil fuel
Blended biomass and fossil fuel briquettes
Other blend of biomass and solid fuel
CHARACTERISTICS WHEN OPERATING WITH THE PREFERRED FUEL
ITEM
HEAT OUTPUT
Nominal heat output:
AUXILIARY ELECTRICITY CONSUMPTION
At nominal heat output
At minimum heat output
In standby mode
Specific precautions for assembly,
installation, or maintenance.
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Business area manager NIBE STOVES
Markaryd, January 1, 2022
NIBE AB / Contura
Box 134, Skulptörvägen 10
285 23 Markaryd, Sweden
info@contura.se
www.contura.eu
+46 433 275100
Contura 600 Style-series 610 (A) / 620 (T) / 690 (A/T)
www.contura.eu
THE RELEVANT HARMONIZED STANDARDS:
EN 13240:2001/A2:2004/AC:2007
CEN/TS 15883:2010
No
6,0 kW
114,7
RRF 40 17 4615, NB 1625
PREFERRED
OTHER SUITABLE
FUEL
FUEL
Yes
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
SYMBOL
VALUE
UNIT
P
6,0
kW
nom
el
-
kW
max
el
-
kW
min
el
-
kW
SB
Fire protection and safety distances to combustible building materials must be observed under all circumstances.
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion
air supply.
EMISSIONS AT NOMINAL HEAT OUTPUT
η
(%)
PM
OGC
S
76,0
<40
<120
76,0
<40
<120
ITEM
SYMBOL
USEFUL EFFICIENCY, BASED ON NET CALORIFIC VALUE (NCV )
Useful efficiency at nominal
η
heat output
TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL
Single stage heat output, no room temperature control
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
With electronic room temperature control plus day timer
With electronic room temperature control plus week timer
OTHER CONTROL OPTIONS
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance control option
CO
NO
x
mg/ Nm
3
(13% O
)
2
<1500
<200
<1500
<200
VALUE
UNIT
86,0
%
th,nom
Yes
No
No
No
No
No
No
No

Publicité

Table des Matières
loading

Table des Matières