Technical Specifications; Performance Graphs - Qlima DCP 624 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4
22
22
man_DCP 624 ('17) V4.indd 22

TECHNICAL SPECIFICATIONS

Model
Voltage
Discharge head
Rated
Flow rate
Tank capacity
Mini splits up to
Sound level
Ambient temperature
Power consumption
Safety switch

PERFORMANCE GRAPHS

FLOW RATE:
Meters head
(m)
0m
2m
28
24
INSTALLATION
Make sure the pump and dehumidifier are unplugged.
Remove the tank from the dehumidifier
Connect the drain tube supplied with the dehumidifier to the unit as subscribed in
the user manual.
Remove the cover of the water tank and place the pump in the tank. The cover can be
placed back once the tank is placed back into the unit but it might fit better without.
Cut the dehumidifier drain tube at such a length that it can be placed in the pump
inlet port once the tank is placed back into the unit.
DCP624
100-230V~/50-60Hz
Max. 10m (33ft)
Non continuous
Max. 24L/h
200ml
8kW
19 dB(A)
o
o
0
C~50
C
3W
NC 3A-250V
Performance (l/h@head)
4m
6m
20
18
Flow in liters/hour
(L/h)
8m
10m
16
12