HIGH EFFICIENCY MEDIA AIR CLEANER INSTALLATION
This air cleaner is designed for use in system up to 2000 CFM. For higher airflows additional units may be
required. See Typical Installation below
IMPORTANT: A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA CARTRIDGE
FROM THE CABINET
1
Turn off the electricity to the furnace
2
Remove front cover
3
Slide media cartridge from air cleaner cabinet, and discard packing material
4
Remove and discard existing furnace air filter
5
Install cabinet in return air system. Properly install airflow direction arrows on interior of
cabinet. Duct supports are recommended to support weight of cabinet. See typical instructions.
6
Slide the media cartridge into the cabinet. Be sure the airflow arrow on the cartridge is in the
same direction as the arrow in the cabinet. The wire mesh is always on the downstream side of
the filter media. Replace cover.
7
If a condition indicator is to be used, install on a vertical duct surface between the air cleaner
and the furnace blower.
8
Turn on electricity and furnace and check performance of all equipment
Canadian General Filters, Ltd 400 Midwest Road Toronto Ontario M1P 3A9
Phone 416-757-3691 Fax 416-757-4687
GF2025-11 Media Air Cleaner
For installation in the return air duct of any
Forced air heating & cooling system
INSTALLATION INSTRUCTIONS