3.2
1.1
RAIN SENSOR
ACTIVE ALARM when
The sensitive surface of the sensor
detects any drops of water.
3.3
1.1
SNOW CONDITION
To manage the alarm associated with snow, the temperature and the rain sensors must be both activated.
ALARM ACTIVATED when
The measured temperature is below 2 °C
and rain has been detected.
3.4
ACTIVATION/DEACTIVATION RAIN SENSOR OR RAIN + TEMPERATURE (SNOW)
Sensor deactivation
Press the "STOP" button of a memorized 7/42
or 3-channel transmitter for 10 s.
The buzzer emits 2 beeps. The procedure
deactivates the sensor for 1 hour.
4.3
1.1
TEMPERATURE SENSOR
The temperature sensor (NTC 10K/3435K) activates whenever there is danger of ice forming.
ALARM ACTIVATED when
The measured temperature is below 2 °C
and the slats are closed.
Once ACTIVE ALARM
The control unit moves the louvres to the complete closing and
it doesn't execute any command. Lr is ON.
What happens with ALARM ACTIVATED
The control unit tilts the slats to 66% of full opening. The control
unit only executes hold-to-run commands.
STOP
(10 s)
What happens with ALARM ACTIVATED
The control unit tilts the pergola slats to 10% of full opening.
LR ON
DEACTIVATED ALARM when
The sensor doesn't detect any drop.
LR flashing
Sensor activation
Press the "STOP" button of a memorized 7/42
or 3-channel transmitter for 10 s. The buzzer
emits a continuous sound.
6
Factory setting
ACTIVATED
Factory setting
DEACTIVATED
ALARM NOT ACTIVE when
The measured temperature is above 3 °C
or rain is no longer detected. If an automatic
opening command is trasmitted, the control
unit exits the alarm state.
STOP
(10 s)
ALARM NOT ACTIVE when
The measured temperature is above 3 °C or
any command is received.
continuous
sound
t
°