INDEX
p. 3 - 5
2.4 Remote memorization of other radio codes
3. SENSORS
p. 5 - 6
3.2 RAIN sensor
3.3 SNOW condition
3.4 Activation/Deactivation rain sensor or rain sensor and temperature (Snow)
4. Technical specifications
p. 7
1
CONNECTIONS AND ADJUSTMENTS
1
2
3
4
LM
5
L1 L2
6
7
8
RN
9
LED
10
DIP SWITCH
11
AN
LED
12
MOTOR STOPS. The control unit stops the motors at the point of a mechanical
stop through current absorption. The threshold can be set with DIP1 and DIP2
(table). Attention! Check that the motor only stops at the mechanical stops
(LM = ON): increase the threshold if the motor stops during operation or
decrease if the motor continues to push against the mechanical stops.
16
-
24Vdc IN
15
+
14
M
13
M
P1
DIP1 DIP2
OFF
WARNINGS
The product at issue must be installed, commissioned and maintained only by licensed and
authorised people, respecting the laws concerning the automatic covers. The system is powered
by 24Vdc. Before the connection to the power supply make sure that the sensors and motors are
correctly connected. A faulty connection of the motors (polarity inversion) could damage them
together with the connected mechanical elements. The power supply must supply the required
voltage and current according to the characteristics of the system. The power supply must be
compliant with IEC60950-1 and must be protected against the short-circuit and over-voltage. Use
a 2x1.5mm cable to connect the motors and the control unit for length up to 6m, or 2x2.5mm cable
for longer segments. PRODUCT DISPOSAL: at the end of this product's useful life, it must not be
disposed of as domestic waste, but must be taken to a collection centre for waste electrical and
electronic equipment. The manufacturer, Teleco Automation s.r.l, declares that the type of radio
equipment is compliant with Directive 2014/53 / EU. The full text of the EU compliance declaration
is available at the following Internet address: www.telecoautomation.com/ce
In the view of a constant development of their products, the manufacturer reserves the right for
changing technical data and features without prior notice.
1
AERIAL GND
2
AERIAL RF
3
4
5
INPUTS COMMON
6
CLOSE/STOP INPUT (N.O.)
7
OPEN/STOP INPUT (N.O.)
8
9
10
RAIN SENSOR (WHITE,+12V)
11
WIND SENSOR (BLUE)
12
WIND SENSOR (BROWN)
13
MOTOR (CLOSE)
14
MOTOR (OPEN)
15
+24Vdc POWER SUPPLY
(A)
16
OFF
1
AN LED WIND SENSOR PULSES
RN LED RAIN SENSOR ACTIVE
2
L1
ON = RAIN ALARM
3
L2
FLASHING = WIND ALARM
4
LM
LIMIT SWITCH LED
P1
PROGRAMMING BUTTON
Default
2