Environment caring
Your appliance does not use any CFC or HCFC. Foaming
agent and refrigerant gas are harmless to the ozone layer
and have zero impact on the greenhouse effect.
Unpacking
Packing material is completely made from recyclable
materials. After unpacking, please take the unnecessary
materials to a recycling point.
1 -
Internal temperature display
2 -
Internal relative humidity display
3 -
Temperature units
4 -
Humidity units
5 -
Setting warning light (temperature / humidity)
Fault Alarm – will show if an alarm is present
6 -
Compressor signal light – on if the compressor is
7 -
working, blinking if the anti-short cycle delay is enabled
Heater signal light – on if the heater is working
8 -
9 -
Dehumidifying action in progress
Temperature setting
Default temperature set point is 12ºC, this is the usual
maturing temperature. However, you can adjust your
cellar between 5 and 20ºC.
Press the temperature setting key (15), actual temperature
set point and signalling light (5) will start blinking.
Adjust to the desired internal temperature using setting
keys UP (13) or DOWN (14), confirm your choice
pressing again the temperature setting key (15).
It is not possible to adjust temperature outside the
appliance working range.
If set point is not changed within 30 seconds, the
controller will return to the default temperature and the
signalling light (5) will switch off.
If the set point is changed but not confirmed, after 30
seconds, the controller will assume the new set point and
return to the display mode.
Electric and electronic equipment disposal
Electric and electronic equipment must be disposed in a
proper manner. If you need to trash your old appliance,
please contact your dealer or the local organisation in
charge of waste disposal.
CONTROLLER ADJUSTMENT
10 -
11 -
12 -
13 -
14 -
15 -
16 -
17 -
18 -
Humidity setting
Default humidity set point is 65%. In order to keep the
sealing quality of the corks and avoid bottle label
damage, internal level of humidity should be ideally
between 60 and 75%. You can however adjust this set
point between 50% and 75%. The appliance will take the
necessary actions to adjust internal humidity to set point.
Please consider that according to the load and the room
conditions, a tolerance of 10% around set point must be
considered.
Press the humidity setting key (16), actual humidity set
point and signalling light (5) will start blinking.
Adjust to the desired internal humidity using setting keys
UP (13) or DOWN (14). Confirm your choice pressing
again the humidity setting key (16).
It is not possible to adjust relative humidity outside the
working range.
7
Humidifying action in progress
Fan signal light – on if the fan is working
LED signal light - on if the light is working
Adjustment key to increase
Adjustment key to reduce
Temperature setting key
Humidity setting key
Charcoal filter key
ON / OFF key – press to stop or restart appliance