Pro Series, CS Single Element Cartridge Pool & Spa Filter
®
Figure 3.
Basic Pool/Spa Combination Plumbing
8.
Support the inlet/outlet pipes independently to
prevent any undue strains.
9.
Place the union nuts over the pipes and clean both
the pipes and union tailpieces with an appropriate
NSF
approved All Purpose cleaner/primer. Glue
®
the pipes to the tailpieces using an appropriate All
Purpose NSF approved adhesive/glue.
NOTE: Zodiac recommends Weld-On 724 PVC
to CPVC Cement to glue Schedule 40 PVC.
10.
Drill pilot holes into the equipment pad with a
¼" masonry bit. Use the holes in the tank bottom
base as a guide.
11.
Install ¼ x 2¼" Stainless Steel Tapcon® screws
and tighten.
3.4
Locking Ring/Tank Top Assembly
Installation
WARNING
Follow these instructions carefully.
Improper locking ring installation can
cause product failure or also cause the
filter lid to be blown off which can result
in death, serious personal injury or
property damage.
1.
Be certain the o-ring is in position in the upper
tank half. Press the filter lid over the lower half
until seated. Lubricating the o-ring with a silicone
based lubricant will help with installation. See
Fig. 4.
2.
Put the locking ring/tank top assembly on the
lower housing and thread it onto the filter. Turn
the locking ring clockwise until you hear it snap
over the tabs on the lower half of the tank.
Heater
Waterfall
Pool Return
|
Installation & Operation Manual
Drain
Outlet
Port
Spa Make Up
Check
Valve
Spa Return
Locking
Ring
Locking Ring
Handle
Figure 4.
Locking Ring
ENGLISH
Inlet
Port
Filter
From Pool
Drain
From Pool Skimmer
Filter Tank,
Upper Half
Filter Tank,
Lower Half
WARNING
This filter operates under high
pressure. Ensure that the locking ring
is turned until it clicks past the stop
tab. Failure to properly install the
locking ring or using a locking ring
that is damaged can cause product
failure or also cause lid separation,
which could result in death, serious
personal injury or property damage.
To avoid injury, keep fingers clear of
the lower tank threads and stop tab.
Page 7
Inlet Port
Pump
Spa Suction
Tabs
O-Ring

Publicité