Optoelektronische Sensoren
Photo electric sensors
Cellules opto-électroniques
OHDM 13P6951/S35A
Laser-Lichttaster mit
Hintergrundausblendung
Diffuse laser sensor with
background suppression
Détecteur réflex laser avec
élimination de l'arrière-plan
Í?*0U7ÂÂ*ÂÄÎ
IND. CONT. EQ
10165323
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone: +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411058 Pune
US-Southington, CT 06489
Phone +91 20 66292400
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/2
Abmessungen
Dimensions
13,4
Teach In
LED
measuring range
1DD2
2
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Tastw eite einstellbar Tw
Tastbereich Tb
Betriebsspannungsbereich Vs (UL-Class 2)
max. Stromverbrauch Mit tel- / Spitzenw ert
max. Schaltstrom
Spannungsabfall
Ansprechzeit / Abfallzeit
Kurzschlussfest
Verpolungsfest
Betriebstemperat ur
Schutzklasse
Laserstrahldurchmesser
* nur Betriebsspannung / Voltage supply / Seulement tension
VORSICHT
Laserstrahl nie auf ein Auge richten.
Es empfiehlt sich, den Strahl nicht ins Leere
laufen zu lassen, sondern mit einem matten
Blech oder Gegenstand zu stoppen.
Technische Änderungen vorbehalten Technical specifications subject to change Sous réserve de modifications techniques
Dimensions
Elektrischer Anschluss
40
PNP
29
6,45
light operate
dark operate
2,1
Dunkelschaltung / dark operate / com. sombre
Hellschaltung / light operate / com. claire
Objekt vorhanden / object present / objet présent
Objekt nicht vorhanden / object not present / objet pas présent
* Senderachse
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
* Emitter axis
• Disconnect power before connecting the sensor.
* Axe de l'émetteur
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
Sensing distance adjustable Tw
Sensing distance Tb
Voltage supply range Vs (UL-Class 2)
max. supply current average / peak
max. switc hing current
Voltage drop
Response time / Release time
Short circuit protection
Reverse polarity protection
Temperature range
Protection class
Laser beam diameter
CAUTION
Do not point the laser beam towards
someone's eye. It is recommended to
stop the beam by a mat object or mat
metal sheet.
Connection diagram
BN (1)
+V
BN = Braun/brown/brun
S
WH (2)
WH = Weiss/white/blanc
ext. teach
BK (4)
BK = Schwarz/black/noir
light/dark
BU = Blau/blue/bleu
Z
BU (3)
0 V
object present
LED
PNP
=HIGH
NPN
=LOW
LED
PNP=LOW NPN=HIGH
Données techniques
Portée ajustable Tw
Plage de détection Tb
Plage de tension Vs (UL-Class 2)
Consommation moyenne / pointe max.
Courant de sortie max.
Tension résiduelle
Temps d'activ ation / Temps désactivation
Protégé contre courts-circuits
Protégé contre inversion de polarité
Température de service
Classe de protection
Diamètre du f aisceau laser
ATTENTION
Ne dirigez jamais le faisceau vers un oeil.
Il est conseillé de ne pas laisser le faisceau
se propager librement mais de l'arrêter au
moyen d'un objet de surface mate.
Schéma de raccordement
object not present
LED
PNP =LOW
NPN=HIGH
LED
PNP
=HIGH
NPN
=LOW
50...550 mm
50...550 mm
12 - 28 VDC
40 mA / 80 mA
< 100 mA
£ 2,8 VDC
£ 5 ms / £ 15 ms
ja / yes / oui
ja / yes / oui *
0...+50°C
IP 67
variabel
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 640...670nm
IEC 60825-1, Ed. 3, 2014
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11
except for conformance with IEC 60825-1 Ed. 3.,
as described in Laser Notice No. 56, dated May 8, 2019