9. Properly dispose of the Sperian Saline Concentrate bottle. Do not reuse.
10. Solution must be replaced 6 months after mixing.
Sperian Water Additive Use
When used as directed, one 8 oz bottle will treat 5-20 gallons of potable water;
1. Wear protective eyewear and gloves and follow sanitary practices during mixing.
2. Use a clean container of sufficient capacity to mix enough solution to fill the eyewash unit. Solution may also be
mixed directly into the eyewash unit.
3. Add half of the required amount of water to the container.
4. Add the appropriate amount of Sperian Water Additive based on station capacity. Mix or agitate thoroughly.
5. Fill the station to the manufacturer's required level.
Any remaining Sperian Water Additive can be stored with the cap on for 120 days after opening. Station should be
cleaned and refilled every 120 days while using this product.
Operation
Employees must be instructed in the use of emergency eyewash stations. (See "Warning," page 1). Studies have
shown that obtaining emergency flushing within the first 10 seconds in eye emergencies is critical. It is required that
training be provided to employees in each department where eye hazards exist. This training should be scheduled on a
regular basis to keep both current and new employees aware of the location of all eyewash devices, as well as to
reinforce the importance of obtaining immediate eye washing in emergencies.
1. The sooner the injured person can flush his eyes, the less likelihood there will be of eye damage. Seconds can make
the difference in preventing serious eye injury or blindness.
2. All employees must be reminded this unit is for emergency use only; tampering with this unit or using it for
non-emegency purposes may cause the unit to fail to operate properly in an emergency situation.
In an emergency, the eyes may involuntarily clamp shut and the individual may be experiencing
pain, anxiety and disorientation. They may need assistance from other workers in getting to and
using the eyewash station.
1. Start the fluid flow by grasping the pull strap and pulling the strap upward.
2. When the fluid is flowing, place the injured person's left hand around the left nozzle
and the right hand around the right nozzle.
3. The injured person should then lower his head into the unit toward his hands.
4. When the eyes are in the streams of fluid, use the thumb and forefinger of each hand
to open the eyelids. Hold eyelids open until thoroughly flushed. 15 minutes is recommended.
5. After flushing, seek medical attention immediately. (See "Warning," page 1).
6. Safety and supervision personnel must be notified that the unit has been used and must
be refilled.

Inspection and Maintenance

1. When filled with flushing fluid, the Fendall Porta Stream II weighs approximately 150 lbs. (70 kg). Provide the necessary
equipment or personnel to install or remove the filled Fendall Porta Stream II from the mounting bracket.
2. Install the mounting bracket so the Fendall Porta Stream II is level.
3. Read all warning notices on the Sperian Saline Concentrate bottle before mixing.
4. Wear suitable eye protection and gloves when mixing the concentrate.
5. Do not add any product or material to the solution of Sperian Saline Concentrate and water.
Inspection
An individual or department must be assigned the task of checking all self-contained eyewash units on a weekly
schedule to ensure the unit is in proper operating condition with adequate levels of flushing fluid. Records of these
weekly inspections should be kept with the unit. Eyewash units containing saline solution or water with an additive
should be cleaned and refilled per the solution manufacturer's recommendations. Units containing just water need to
be cleaned and refilled once a week. Use of a fluid beyond the expiration date may result in serious personal injury. (See
"Warning," page 1).
NOTE:
The Sperian Saline Solution contains a specially formulated salt compound. There may be a white residue if solution
has dried on the Fendall Porta Stream II surfaces. The white residue can be removed by wiping with a damp cloth.