Fendall Porta Stream
15-Minute Emergency Eyewash Station
16-Gallon (61 liters) Model #32-000200/32-000230 Installation and Operation Manual
Unpack and Inspect
The Fendall Porta Stream II is delivered in one (1) box. Upon receipt,
check the shipping box for any damage. The following items
are contained in the box (please check the last page for other
items that may be included for your specific model):
1. Fendall Porta Stream II Station
2. Pull Strap
3. Metal Hanging Bracket
4. Installation and Operation Manual
!
• The unit must be level for proper operation. (See "Choose a Location," page 1).
WARNING:
• The Fendall Porta Stream II may weigh over 150 lbs. (70 kg) when filled with solution. Assistance
may be required when installing the unit on the hanging bracket. (See "Choose A Location," page 1).
• Do not add any product or material to the solution of Sperian
Fendall Porta Stream II," page 2).
• Employees must be instructed in the use of emergency eyewash stations. (See "Operation," page 3).
• This emergency eyewash unit is intended for the emergency use of victims of eye contamination until
medical treatment is obtained. In all cases, the victim should seek medical attention immediately after
flushing. (See "Operation," page 3).
• An individual or department must be assigned the task of checking all self-contained eyewash units on a
weekly basis. (See "Inspection and Maintenance," page 3).
• All eyewash devices containing Sperian Saline or Sperian
per solution manufacturer's recommendations. Units containing just water need to be cleaned and
refilled at least once a week. (See "Inspection and Maintenance," page 3).
• Use of a fluid beyond the expiration date may result in serious personal injury. (See "Inspection and
Maintenance," page 3).
Failure to follow and comply with all instructions and cautions stated in this manual may result in serious personal
injury, serious illness, blindness or death.
Choose a Location
1. The unit shall be positioned with the nozzle(s) not less than 83.8 cm (33 in). and no greater than 114.3 cm (45 in). from the floor
and 15.3 cm (6 in). minimum from the wall or nearest obstruction.
2. Eyewash units shall be in accessible locations that require no more than 10 seconds to reach. The eyewash shall be located on
the same level as the hazard and the path of travel shall be free of obstructions that may inhibit the immediate use of the
equipment. For a strong acid or a strong caustic, the eye wash should be immediately adjacent to the hazard.
3. Each eyewash location shall be identified with a highly visible sign positioned so the sign shall be visible within the area served
by the eyewash. The area around the eyewash shall be well lighted.
The Fendall Porta Stream II emergency eyewash station must be installed in an easily accessible location in the
immediate area of hazard to the employee, according to ANSI Standard Z358.1-2004 requirements. The Fendall
Porta Stream II may be placed on any level surface of required height, such as a table or bench (allow for proper
drainage and disposal of the flushing solution). The Fendall Porta Stream II may also be mounted on a wall or post
using the metal hanging bracket. The unit must be level for proper operation. (See "Warning" on page 1).
Sperian Eye & Face Protection, Inc • 825 E. Highway 151 • Platteville, WI 53818 • 1-800-336-3255 • www.sperianprotection.com
II
®
Fendall Porta Stream II Station
Installation
and Operation
Manual
The ANSI Standard Z358.1-2004 requires that:
Part No. 32-003805 Rev G
Pull Strap
®
Saline Concentrate and water. (See "Fill the
Water Additive should be cleaned and refilled
®
Nozzle Assembly
Metal Hanging
Bracket