Figure 7
NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is
designed to only fit one way.
SECTION 5
Wiring
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION:
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1.
Wiring Fan/Light Independently: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and two hot
(black lead connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan's receptacle.
1a. From where you have access to inside the fan's junction box, connect the one white wire
from the house to both the white wire from the fan's light receptacle and the white wire
from the fan's exhaust receptacle. Connect the first black wire from the wall switch to the
red wire from the fan's light receptacle. Connect the second black wire from the switch to
the fan's exhaust receptacle. Connect the ground wire from the house to the green wire
from the fan's grounding screw (Figure 8). Use approved methods for all connections.
Supply
from
house
Figure 8
2.
Wiring Fan/Light together: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and one hot
(black lead connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan's receptacle.
2a. From where you have access to inside the fan's junction box, connect the one white wire
from the house to both the white wire from the fan's light receptacle and the white wire
from the fan's exhaust receptacle. Connect the black wire from the wall switch to both the
red wire from the fan's light receptacle and the black wire from the fan's exhaust receptacle.
Connect the ground wire from the house to the green wire from the fan's grounding screw
(Figure 9). Use approved methods for all connections.
Supply
from
house
Figure 9
210572063 Rev. F 2-17
MAKE SURE POWER IS SWITCHED OFF AT
ALL ELECTRICAL CONNECTIONS MUST BE
Ground
White
Hot (Black)
Hot (Red)
Ground
White
Hot (Black)
Hot (Red)
SECTION 6
Completing the Installation
1.
Reinstall the fan's venturi by holding it at approximately a 45 degree angle, hook the two
tabs on the venturi into the slots on the housing and secure in place by tightening the
venturi screw. Rotate the blower wheel by hand to ensure it spins freely. Now plug the
fan motor into the receptacle (Figure 10).
Figure 10
2.
Remove glass light lens from grill by unscrewing knob at the top of lens (Figure 11).
Glass Lens
Figure 11
Plug cord from lamp holders into the appropriate receptacle (Figure 12).
3.
Figure 12
4.
Line up slots in the grill with lances on inside of housing. Insert included #8 screws
through grill slots and into housing lances. Tighten both screws until the grill fits snugly
to the ceiling. DO NOT OVER TIGHTEN (Figure 13).
Figure 13
CAUTION:
IN A RATTLING OR HUMMING NOISE.
5.
Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included).
www.airkinglimited.com
Knob
#8 Screws
FAILURE TO SECURE THE REFLECTOR BOLT MAY RESULT
Cord
Lamp
Holder
Lances
Grill
3 of 12