Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: DL4D, DL4DG,
DL4DH, DL4DGH
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727903 Rev. D 10-16
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) Do not install in a ceiling with thermal insulation value greater than
R40.
g) This unit must be grounded.
h) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
i)
Read all instructions before installing or using exhaust fan.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
CAUTION:
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

loading

Sommaire des Matières pour AirKing DL4D

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: DL4D, DL4DG, Exhaust Fan with Light DL4DH, DL4DGH READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan.
  • Page 3 NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and the wire stripped. Screw Motion Sensing Models For two speed fans wired for continuous ventilation, connect the White wire of the fan to the White (Neutral) wire from the power source.
  • Page 4 SECTION 7 If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in Section 5 (Wiring), Step 1b. Programming the Occupancy Sensor STANDARD MODELS: Plug the fan’s Motion 1a. Setting the Occupancy Time Delay. This will set the amount quick connect motor cord into the of time the fan will continue to operate on high speed after the corresponding receptacle located on...
  • Page 5 SECTION 10 Fuse Follow the steps in SECTION 5 Wiring to gain access to the Use and Care fuse holder located inside the wire compartment. To replace the fuse, squeeze the top an bottom of the fuse holder together CAUTION: MAKE SURE POWER IS SWITCHED OFF AT while twisting the larger piece in a direction away from the SERVICE PANEL BEFORE SERVICING THE UNIT.
  • Page 6 5S1202123 Blower Assembly 5S1250100 Fuse Harness Assembly 5S1250011 Light Lens 5S1239116 8 Watt LED Lamp 5S1250001 Specific to Model DL4D Qty. Description Replacement Part # Grill Assembly 5S1250105 Wire Compartment Assembly 5S1250104 Specific to Model DL4DG Qty. Description Replacement Part #...
  • Page 7 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur combiner, comprend Modèles: DL4D, DL4DG, DL4DH, DL4DGH lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9 REMARQUE : Le fil jaune peut contenir un écrou de fil à sertir qui devra être coupé et le fil dénudé. Modèles avec détection de mouvement Pour les ventilateurs à deux vitesses, raccordés pour une ventilation continue, connectez le fil blanc du ventilateur au fil blanc (neutre) de la source d’alimentation. Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur.
  • Page 10 SECTION 7 MODÈLES STANDARDS: branchez le Mouvement cordon de connexion rapide du moteur du Programmation du capteur d’occupation ventilateur dans la prise correspondante située sur le couvercle du compartiment de 1a. Réglage du délai d’occupation. Ceci va régler la durée de fil.
  • Page 11 SECTION 10 Lumière de Nuit : dévisser l’ampoule de lumière de nuit de son socle et la remplacer avec une ampoule de lumière de nuit de type C7 d’un maximum de 4 watts (culot de Utilisation et entretien type candélabre. ATTENTION : Fusible VOUS ASSURER QUE L’ALIMENTATION...
  • Page 12 Assemblée de la Soufflante 5S1250100 Assemblage du harnais de fusible 5S1250011 Objectif de lumière 5S1239116 Lampe de 8 watts à LED 5S1250001 Particularités de modèle DL4D # de pièce de Qté. Description remplacement Assemblée de Grille 5S1250105 Assemblée du compartiment du fil 5S1250104 Particularités de modèle DL4DG...

Ce manuel est également adapté pour:

Dl4dgDl4dhDl4dgh