Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
EN ZSDR-850 ZIGBEE SMOKE DETECTOR
1. REMOVE BATTERY PULL STRIP
Remove the detector from the mounting bracket by twisting it.
A
Remove the battery pull strip by pulling it from the detector.
B
Only after removing the pull strip the detector can be used.
2. INDICATORS
The detector contains a LED indicator to show the status of the
detector. Please see below the meaning of the different LED
indications.
LED FUNCTION TABLE
Connection mode
LED will flash fast for approximately 1 min.
Connected successfully
LED will light up for 3 sec (The App will also
indicate when the connection is successful)
Detector reset
LED will flash 6x
Detector alarm
LED will flash and detector will sound (85db). To
stop the detector alarm press the Test/Stop button
Detector operation
LED will flash once every 53 sec to indicate the
detector is operating correctly
Battery low indication
LED will flash once and gives one beep every
53 sec
8
ZSDR-850 ZIGBEE SMOKE DETECTOR EN

3. DOWNLOAD APP

To connect the detector with a
Z1 Zigbee bridge or ICS-2000,
first get the App by scanning
the QR code or go to trust.com/
Zigbee and install it.
4. CONNECT DETECTOR
In the App, select a room,
A
press the + button and
choose Trust Zigbee line/
Smoke detector and follow the
instructions. For manual set up
of push-notifications go to the
rules tab, press the + button
and select notification wizard.
5. MOUNT THE DETECTOR
Mount the bracket of the
A
detector on a flat surface on
the ceiling and secure it with
the included screws.
Place the detector on the
B
1
mounting bracket.
Secure the detector by
2
twisting it on the bracket
to lock it.
6. TEST MODE
Activate the test mode of the
detector to check the operation
by pressing the Test/Stop
button. The LED will flash fast
and the detector will sound.
RESET DETECTOR AND
ACTIVATE CONNECT MODE
Warning: This step will
disconnect the detector from
the Z1 Zigbee Bridge or the
ICS-2000. To reset the detector
press the button in the hole
at the side for approximately 5
sec with the included pin. The
LED will flash 6x to confirm
the reset.
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

71197

Table des Matières