AUDIO VIDEO IP KIT
CONNECTION
Power supply connection (24VDC)
The required power supply is 20Vdc at 30Vdc.
Note: The door entry station can be powered by PoE+ or PoE
Ethernet (with some restrictions)
Your device is delivered from the factory in PoE / PoE+
configuration, however in some cases it may be necessary to
block it in a PoE configuration alone (distribution of the power of
the Switch on several gatekeepers / poor power management of
the Switch /. ..).
In this case with the device not powered and with a small non-
conductive clamp, remove the strap indicated in red on the
photo below
IP network connection (ETH0 / ETH1)
The connection is made via a 10/100/1000 Mbits Ethernet RJ45 link.
2 Available Ethernet port (1 PoE or PoE+ and 1 non PoE compatible)
Magnetic Loop Loop Output Connection (Loop)
A Loop output allows the connection of the magnetic induction loop.
Connection of 0dB output (0dB +/-)
A 0dB differential output allows the connection of an external amplifier.
+: hot spot
-: cold point
0V: GND
Connection to the VDIP RS485 bus
The device is connected to the VDIP RS485 devices (VD4S réf 110.1000, VD8EI réf 110.1100, VDLECT réf
110.1200) via a RS485 bus line (bus wiring: several devices can be installed on one bus line).
The bus connection between the peripherals and the module is made by points RS1 and RS2 (via a twisted pair) and
the ground. Establish the point-to-point connection by following the order of the signals.
The maximum length of the bus is 1 km. A 120 ohm resistor needs to be fitted (provided with the RS485 device)
between points RS1 and RS2 at each end of the bus.
Input connection (IN1 / IN2 / 0V)
Two digital inputs allow the connection of a dry contact (do not apply voltage). To be activated, the input must be
grounded.
The contact can be deported up to 1Km.
Connection of relay outputs (RL1 / RL2)
The connection is made via a 3-point terminal block providing the "Common (C) / Rest (NC) / Work (NO)" interface.
If you use one of these relay outputs to control an AC or DC strike, wire a non-polarized 58V diode in parallel to the
dry contact between C and NO or C and NC depending on use (diode supplied).
Audio induction loop output connection (Loop)
A Loop output connects the audio induction loop.
Possibility of connecting the loop ref.: 590.9040 for better range.
Microphone connection (Mic+/Mic-)
The connection is made with a 1 pair polarised cord and the kit's screw terminal.
Connect the microphone's white wire to Mic+ of the kit terminal.
Connect the microphone's blue wire to Mic- of the kit terminal.
Technical data sheet no. EN-604-0092C
Applicable from software version 1.5.0
Configurable with CASTELSuite
www.castel.fr
FR
EN
Page 12 / 20