Order; Electrical Specifications - PR HART 5106 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2-wire transmitter
Current, mA
22
Output
Supply
Type
5106

Electrical specifications:

Specifications range:
Output
-20 to +60°C
Common specifications:
Supply voltage universal ............................. 21.6...253 VAC, 50...60 Hz or
Supply
Internal consumption .................................. ≤ 2 W (2 channels)
Max. consumption....................................... ≤ 3 W (2 channels)
Fuse ............................................................. 400 mA SB / 250 VAC
Isolation voltage, test / operation ............... 3.75 kVAC / 250 VAC
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%) .......... < 25 ms
Calibration temperature............................... 20...28°C
Effect of supply voltage
change (24...250 V) ..................................... < ±10 µA
Accuracy, the greater of general and basic values:
Input type
mA
Input type
mA

Order: 5106

Version
Input
Standard
: A
4...20 mA : B
[EEx ia] II C : B
19.2...300 VDC
General values
Absolute
accuracy
≤ ±0.1% of span
≤ ±0.01% of span / °C
Basic values
Basic
accuracy
≤ ±16 µA
Output
Channels
4...20 mA : 2
Single
: A
20...4 mA : 9
Double
: B
Temperature
coefficient
Temperature
coefficient
≤ ±1.6 µA/°C