SERVICE & MAINTENANCE
WARNING:
1 . Remove 8 bolts to disassemble the
backing from the ventilation panel .
2 . Remove screws holding the ActivePure®
Cell in place .
3 . Slide the used cell out and discard .
4 . It is recommended maintenance to
vacuum off the vent openings and clean
the underside of the unit if any dust
build-up has accumulated .
NOTE: A face mask should be worn to
prevent inhalation of any particles
released into the air during the
process . Eye protection may be
necessary when cleaning the unit
from below while it is mounted in
the ceiling .
5 . Slide the new ActivePure® Cell into place .

Replacement part:

ActivePure® Cell (Ozone-Free)
Item # 49785
6 . Reinstall the screws securing the
new cell into position .
7 . Replace the backing using the
same 8 bolts previously removed .
8 . Mount unit back into ceiling .
9 . Reconnect Power Supply connections
and turn the Power Switch on .
6
All manuals and user guides at all-guides.com
Service should only be performed by a qualified electrician. Make sure the
Power Switch is turned off and wiring is disconnected prior to handling .
Turn the Power ON / OFF switch to ON.
OWNER'S MANUAL SUPPLEMENT
- Fan Speed Toggle Switch –
Toggle Switch
Power Switch
Read and follow all instructions in the Owner's Manual.
ActivePure Cell
TOGGLE SWITCH