6.
Putting into service and operation
Left-hand, red LED (light-emitting diode): If the charger is connected to the AC line and
the left-hand LED goes red, the charger is OK. If the LED is red and flashing, the
charger has a fault.
If there is a fault, the left-hand LED is red and flashing. This indicates a charger mal-
function - further charging is not possible. A new or long time not used battery gets its
full power after 5 charge and discharge cycles.
7.
Charging procedure
Voltage, temperature, short-circuits and polarity checks are made on inserted batteries.
Before charging is started, the safety elements (Bi-metal or NTC) will be checked over
the temperature contact.
Flashing red (right-hand LED): Because of the intelligent charging the charging state of
the insert battery will be determined during the first 4 seconds.
Charging state detection is a special feature of this charging method. By modifying the
charging current, it is possible to prevent excess internal battery pressure and a rise in
the charging voltage.
Flashing green (right-hand LED): The battery is fully charged. Because of this charging
version the battery will be protected and always fully charged.The battery can be left in-
definitely in the charger without sustaining any damage. Overcharging is impossible.
Flashing red (right-hand LED): The LED indicates that the battery temperature is not
within the rapid charging temperature range of 5°C - 40°C. As soon as the allowable
temperature range is reached, the battery charger automatically switches to rapid
charging.
Continuous red (right-hand LED): The battery is defective.
LED left red
red LED continuous
red LED flashing
LED right, multi-coloured
green LED
continuous
green LED flashing
red LED continuous
red LED flashing
6 / 12
All manuals and user guides at all-guides.com
Original operating instructions charger BCH-3100
Charger is connected to
the AC and ready for
operation
Charger is defective
Charging started
Battery is fully charged
Battery is defective
Battery is too hot or too
cold