Before use, make sure that the tool is correctly fixed and fastened. Let it run idle for about 30
seconds in a safe position. If considerable vibrations occur or if other defects are recognised, switch
off immediately.
.
Always lead the mains and extension cable as well as the extraction hose to the back away from the
machine.
.
Power tools have to be inspected by a specialist in regular intervals.
.
Never carry the machine at its cable.
.
Do not touch rotating parts.
.
Persons under 16 years of age are not allowed to use the tool.
.
During use, the operator and other persons standing nearby have to wear suitable ear
protectors, a dust mask and protection goggles.
.
Make sure that persons in the work space are not endangered by particles flying around.
.
Keep the handles dry, clean and free of oil and grease.
.
During operation, always hold the tool with both hands.
.
Attention! The tool still runs for a little while after the machine was switched off.
For further safety instructions, please refer to the enclosure!

6 Electrical Connection

Before starting the machine check the correspondence between voltage and frequency according to the data
mentioned on the identification plate. Voltage differences from + 6 % and – 10 % are allowed.
The grinder is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section which is too small could cause a
considerable drop in performance and an overheating of machine and cable.
The tool includes a start-up speed limiter to prevent fast expulsion fuses from unintended responding.
Recommended minimum cross-sections and maximum cable lengths:
Mains voltage
230V
en
Cross section in sq. mm
1.5
45 m
HGE125
2
2.5
75 m