Operation; Function Test; Temperature Indication - Danfoss Heating SH-E01 Instructions D'installation

Régulateur électronique de chauff age solaire
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
Fit the temperature sensors in the immersion pockets - in the solar
collector and at the bottom of the hot-water tank. The cables are 3 m,
but can be extended as required by 2 x 0.75 mm
cable. EMC approved for 50 m cable length.

4.0 Operation

4.1 Function Test

The regulator is ready for operation when connected the mains. The
display becomes active and current temperatures are shown.
Display updates once per minute. Pressing the INFO button causes
the display to update immediately.

4.2 Temperature Indication

Solar Collector
°C
Display
F1 flashes
200
150°C flashes
150
Temperature flashes
120
Operating Range
0
Temperature flashes
-9
-9°C flashes
-40
F1 flashes
Danfoss Heating
Tank
Meaning
°C
Sensor fault/alarm
High temperature
120
99
85
0
Low temperature
-40
Sensor fault/alarm
2
double-insulated
Display
Meaning
Sensor fault/alarm
F2 flashes
99°C flashes
HIgh temp./alarm
Temperature flashes
Operating Range
0°C flashes
Low temperature
F2 flashes
Sensor fault/alarm
GB
D
DK
F
ES
PT
7

Publicité

Table des Matières
loading

Table des Matières