1. MOUNTING AND WIRING THE LIGHT
Note: Do not mount on the ground, recommended installation height is 6 ½ feet to 10 feet
** Before you begin make sure that your power is turned off at your circuit breaker box **
1. Install the cross bar (E) to the junction box and secure with the (2) mounting screws (I).
2. On the cross bar locate GND, attach the ground wire (G) with the grounding Screw (F)
to the cross bar.
3. Use a wire nut (H) to connect the ground wire (G) to the house ground wire (typically copper).
For proper connection, place wire nut over wires and twist clockwise until tight.
4. Connect supply wires with wire nuts (H) as shown in the figure above.
• Black supply wire connects to the Black power supply wire (Live)
• White product wire connects to the White supply wire (Neutral)
5. You may use the optional gasket (D) at this time.
6. Install the light fixture (A) to the cross bar (E). Use silicon sealant (not included) around the perimeter
of the light to seal for moisture.
7. Screw in the stainless steel screw (C) to hold fixture in place.
Insert plastic screw cover (B) into screw hole.
8. Turn on your electricity after the install has been completed.
9. Turn on power switch. (If power switch is not on, the light will not cycle on or off)
2. ADJUSTING YOUR LIGHT HEADS
Your light heads can be adjusted by turning the individual light head to desired position. You can also adjust your light head
up and down to your desired position.
WARNING : Risk of fire. Do not aim the bulbs at a combustible surface
within 3 ft. (1m)
3. ADJUSTING YOUR MOTION SENSOR
Your sensor head can be adjusted by turning the individual up and down to your detection distance.
INSTALLATION
Note: Mount the fixture higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
ATTENTION: Keep the sensor at least 2" (51 mm) away from the lamps.
4. SETTING THE MOTION SENSOR
SENSOR ADJUSTMENTS
** You must adjust the motion sensor on the light to the desired area
before you can adjust the time and LUX settings**
TIME SETTING
The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases.
The minimum time (slide switch) is approx. 5 seconds, the maximum time (slide switch) is approximately 12 minutes.
Set the slide switch to control to the desired setting between these limits.
LUX SETTINGS
The LUX slide switch knob control determines the level of darkness required for the unit to start operating.
The setting is best achieved by the procedure below:
• Set the slide switch knob to the "Night" position on behalf of sensors to work only at night (about : 0-20lux)
• Set the slide switch knob to the "Dusk" position on behalf of sensors in the environment into the twilight state
can work (about : 0-200lux)
• Set the slide switch knob to the "Day" position on behalf of sensors in the environment on behalf of the state can work
during the day (about :0-2000lux)
SENS SETTINGS
The SENS slide switch knob control :
Set the slide switch knob to the "Min" position. The sensor is low sensitivity setting.
Set the slide switch knob to the "Mid" position. The sensor is generally sensitivity setting.
Set the slide switch knob to the "Max" position. The sensor is high sensitivity setting.

Publicité