PRODUCT SPECIFICATIONS
• Detection Method: PIR (Passive Infrared)
• Detection Range: Max.70ft
• Detection Angle: Up to 240°
• LED Angle: 120°
• Time Adjustment: (minimum) 5 seconds to 1, 5, 12 minutes
• Operating Voltage: 110 ~240 volts 50Hz/60Hz
• IP Rating: 44
Note : Sensor has a 1 1/2 minute warm up period before it will detect motion. when first turned on, wait 1 1/2 minutes.
TROUBLESHOOTING GUIDE
SYMPTOM
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
Lights will not come on
4. Daylight turnoff is in effect (recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover desired area
Lights come on in day light.
Light control may be installed in a relatively dark location.
Light control may be sensing small animals
Lights come on for
or automobile traffic (re-aim sensor).
no apparent reason.
Range is set too high. (Reduce Range setting).
1. A lamp is positioned too close to the sensor or pointed
at nearby objects that cause heat to trigger the sensor.
(Reposition the lamp away from the sensor or
Lights stay on continuously.
nearby objects).
2. Reduce sensitivity.
1. Heat or light from the lamps may be turning the light
control on and off. (Reposition the lamps away from
the sensor).
Lights flash on and off.
2. Heat being reflected from other objects may be affecting
the sensor. (Reposition sensor).
PRODUCT MAINTENANCE
To clean the surface of the light, use mild soap and water.
Do not use scouring pads, powders, steel wool or any other abrasive materials. Do not immerse in water.
POSSIBLE CAUSE
INSTRUCTIONS
LED MOTION SENSOR SECURITY LIGHT
Item: 4-80053 / 4-80054
IMPORTANT SAFETY INSTRUCTIONS
Before you begin installing, servicing, or maintenance of this product, follow these general precautions.
• For commercial installation: service and maintenance of this product should be performed by a qualified, licensed electrician.
• For residential installation: If you are unsure about the installation or maintenance of this product, consult a qualified
licensed electrician.
• Do not mount the unit against flammable surfaces.
• This product is intended to be used outdoors, and be subject to the elements; such as rain and snow and we recommend it
to be mounted at least 6' 6" off the ground
• This LED product must be powered directly to a switched circuit. (on/off).
• This product should not be used in areas with limited ventilation or high ambient temperatures.
• This product CAN NOT be used with a dimmer switch, motion or occupancy sensor or other electronic switching device.
• This product is intended to be connected to a properly installed and grounded UL listed junction box.
WARNING: RISK OF ELECTRICAL SHOCK
• Turn off electrical power at fuse or circuit breaker box before wiring product to the power supply.
• Verify voltage is 110V-240V before installing.
• Make all electrical and grounded connections in accordance with the National Electric Code and any applicable local code
requirements and All wiring connections should be capped with UL listed wire connectors.
CAUTION: RISK OF PRODUCT DAMAGE
• Never connect fixture with power on.
• Avoid covering LED products with insulation, foam, or other materials that will prevent convection or conduction cooling.
• Never connect an LED product directly to dimmer packs, occupancy sensors, timing devices, or other related control devices,
unless individual product specifications deem otherwise.
• LED products are polarity sensitive, ensure proper polarity before installation.
• Do not touch the individual electronic components, it may cause ESD (Electronic Discharge), shorten lamp life
or alter performance.
CAUTION: RISK OF INJURY
• Avoid direct eye exposure to the light source while it is on.
• Let it cool completely before handling.
INSTALLATION INSTRUCTIONS
PART
DESCRIPTION
QUANTITY
A
Light Fixture
1
B
Plastic Screw Cover
1
C
Stainless Steel Screw
1
D
Gasket (optional)
1
E
Cross Bar
1
F
Grounding Screw
1
G
Grounding Wire
1
H
Wire Nut
3
I
Stainless Steel Mounting Screws
2
Silicon Sealant recommended (not included)
Tools Required for Installation: Phillips screwdriver, level

Publicité

loading

Sommaire des Matières pour Tricity 4-80053

  • Page 1 • Detection Method: PIR (Passive Infrared) • Detection Range: Max.70ft • Detection Angle: Up to 240° • LED Angle: 120° LED MOTION SENSOR SECURITY LIGHT • Time Adjustment: (minimum) 5 seconds to 1, 5, 12 minutes Item: 4-80053 / 4-80054 • Operating Voltage: 110 ~240 volts 50Hz/60Hz IMPORTANT SAFETY INSTRUCTIONS • IP Rating: 44 Before you begin installing, servicing, or maintenance of this product, follow these general precautions. • For commercial installation: service and maintenance of this product should be performed by a qualified, licensed electrician.
  • Page 2 1. MOUNTING AND WIRING THE LIGHT 3. ADJUSTING YOUR MOTION SENSOR Note: Do not mount on the ground, recommended installation height is 6 ½ feet to 10 feet Your sensor head can be adjusted by turning the individual up and down to your detection distance. ** Before you begin make sure that your power is turned off at your circuit breaker box ** INSTALLATION Note: Mount the fixture higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance. ATTENTION: Keep the sensor at least 2” (51 mm) away from the lamps. 4. SETTING THE MOTION SENSOR 1. Install the cross bar (E) to the junction box and secure with the (2) mounting screws (I). 2. On the cross bar locate GND, attach the ground wire (G) with the grounding Screw (F) to the cross bar. 3. Use a wire nut (H) to connect the ground wire (G) to the house ground wire (typically copper).
  • Page 3 INSTRUCTIONS • Méthode de détection: PIR (infrarouge passif) • Plage de détection: Max.70ft • Angle de détection: Jusqu’à 240 ° • Angle de LED: 120 ° DEL DÉTECTEUR DE MOUVEMENT • Réglage du temps: (minimum) 5 secondes à 1, 5, 12 minutes Item: 4-80053 / 4-80054 • Tension de fonctionnement: 110 ~ 240 volts 50Hz / 60Hz INSTRUCTIONS DE SÉCURITÉ IMPORTANTES • Indice IP: 44 Avant de commencer l’installation, l’entretien ou la maintenance de ce produit, suivez ces précautions générales : • Utilisation commerciale: le service et la maintenance de ce produit doivent être effectués par un électricien agréé qualifié. Note : le Capteur de mouvement a besoin d’une période de réchauffement de 90 secondes pour la première utilisation • Utilisation résidentielle: Si vous ne savez pas comment utiliser le câblage électrique, il est recommandé de recourir aux services d’un électricien compétent pour s’assurer que l’installation soit conforme aux normes de la région et du pays.
  • Page 4 1. MONTAGE ET CÂBLAGE LA LUMIÈRE 3. AJUSTEMENT DE VOTRE CAPTEUR DE MOUVMENT Note: Hauteur de montage recommandée est de 6 ½ pieds à 10 pieds Le capteur peut être réglé individuelle de la tête pour ainsi désigner la zone de détection. ** Avant de commencer, assurez-vous que votre alimentation est coupée à votre boîte de disjoncteur ** INSTALLATION Note: Pour de meilleures performances, monter la fxture environ 8 pi. (2,4 m) au-dessus du sol. ATTENTION: Garder le capteur au moins 2 “(51 mm) des lampes. 4. CONFIGURATION DU CAPTEUR DE MOUVEMENT 1. Installez la barre transversale (E) à la boîte de jonction et le fixer avec les vis (2) de montage (I). 2. Sur la barre transversale localisez GND, fixez le fil à la mise à terre (G) avec la vis pour la mise à la terre (F) à la barre transversale. 3. Utilisez l’écrou (H) pour connecter le fil à la mise à terre (G) au fil maison (généralement en cuivre). Pour une connexion correcte, placez écrou sur les deux fils et tourner dans le sens horaire jusqu’à la butée. 4. Connecter les fils d’alimentation avec les écrous de fil (H) comme indiqué dans la figure ci-dessus ;...

Ce manuel est également adapté pour:

4-80054