Honeywell Home RPLS730B Mode D'installation Et D'emploi page 3

Interrupteur mural programmable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
PROGRAMMING THE SCHEDULE
You can set up to 7 programs. To set a program, you need to enter its start
time (ON) and its end time (OFF).
1.
Pry the switch door open using a small screwdriver.
2.
Press the PGM button to display a program and its
On or Off time. For example, when you first press
PGM, program number 1 (P1) and its On time (ON)
will appear. - : - - will appear instead of the time if the
program is not set (inactive).
3.
Press the DAY button to select the day to which you
want to apply the program.
4.
NOTE: If you want to apply the program to every day
of the week, press DAY until all the days are
displayed. (This still counts as 1 program, not 7)
5.
Press the HOUR and MIN buttons to set the ON time
(time when you want the lights to turn on). If you have selected the 12-
hour format, ensure that PM appears on the screen when an afternoon
time is displayed.
6.
After you have programmed the ON time, press the PGM button to
display the OFF time (time when you want the lights
to turn off).
7.
Repeat steps 3 through 5 to program the OFF time. If
the program ON time is set for every day of the week,
the program OFF time will automatically be set for
every day.
8.
To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
9.
Press one of the control buttons or close the switch door to return to
normal operation.
Clearing a programmed time
Press the PGM button as many times as needed to display the programmed
time. Hold the PGM button for 3 seconds. - : - - appears when the
programmed time is erased.
TROUBLESHOOTING
Blank display
Faded or irregular display
Cannot switch between 24-hour
format and 12-hour format
Programs do not run as expected
The switch resets itself without
apparent reason when used to control
an inductive load such as a relay or a
contactor.
Verify circuit breaker at main panel.
Ensure the ON/OFF selector is at ON.
Reset the switch using a paper clip.
Ambient temperature below freezing point
First, press one of the control buttons so that
or
appears on display.
MAN
AUTO
Make sure the switch is properly programmed.
Note that - : - - indicates an inactive program.
If the switch has been configured for 12-hour
format, check that PM appears on the left side of
the screen when an afternoon time is displayed.
The reset is caused by the load. Install a snubber
(AC130-03) at each relay/contactor.
3
M38500
M38501
69-2457EFS—03

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rpls731b

Table des Matières