Rules For Safe Installation
and Operation
To prevent possible
serious or fatal injury and/or dam-
age to equipment, system pressure
must be less than 75 pounds per
square inch (PSI) under any circum-
stances. Failure to follow this in-
struction can result in tank blowup.
Install relief valve in system be-
tween pump and tank capable of
passing entire pump output at 75
PSI.
Do not allow pump,
tank or piping system to freeze.
Freezing can severely damage
equipment and may lead to tank
explosion and serious injury.
Allowing tank to freeze voids warranty.
1. Follow local codes when installing
tank.
2. Test well water for purity before
using it.
3. Disconnect power to pump and re-
lease all pressure in system before
installing or servicing tank.
4. Drain all water from system before
performing any maintenance on
tank.
Installation
1. Use teflon tape on threaded pipe
joints to tank. DO NOT use pipe joint
compound on plastics, as it may
damage the plastic.
2. Install air volume control according
to instructions supplied with air vol-
ume control.
3. Connect inlet and outlet pipes as
shown in illustration.
4. When installing tank in a system
having a submersible well pump, be
sure that orifices are installed and
operating correctly. See Submer-
sible pump owner's manual for more
information.
Pro-Source, Delavan, Wisconsin 53115 USA • Ph. (262) 728-5551
Installation and Operation Instructions
Models AW12H, AW30H, AW42, AW42T, AW85, AW120
Typical Jet Pump Installation
Compression
To
Fitting
Service
Typical Jet Installation with Horizontal Tank
Pressure
Gauge
Pressure
Switch
To
Service
Typical Submersible Installation
Control Box
(3 Wire Models Only)
Union
From Well
Relief
Valve
Gate Valve
Air-Over-Water Tanks
Pressure
Gauge
AVC
Relief
Valve
Plastic
Tubing
Compression Fitting
Regulator
Screw
Relief
Valve
Pump
Plastic
Tubing
Compression
Fitting
Compression Fitting
Pressure
Gauge
Electrical
Disconnect
Air Volume
Control
(U238-14)
Pressure Switch
Pump
AVC
To House
Service
146 0893 SR
S515 (Rev. 8/31/00)

Publicité

loading

Sommaire des Matières pour Pro-Source EpoxyLine AW12H

  • Page 1 Service operating correctly. See Submer- sible pump owner's manual for more information. From Well Relief Valve Pressure Switch Gate Valve 146 0893 SR Pro-Source, Delavan, Wisconsin 53115 USA • Ph. (262) 728-5551 S515 (Rev. 8/31/00)
  • Page 2 LIMITED WARRANTY Pro-Source, warrants to the original consumer of the products listed below, that they will be free from defects in material and workman- ship for the Warranty Period from the date of original installation or manufacture as noted. Product...
  • Page 3 à la Notice d'utilisation des pompes submersibles pour plus de Lim. Soup. Relief Contacteur Manométrique e pression Valve Pressure Switch détails. Gate Valve 146 0893 SR Robinet-vanne Pro-Source, Delavan, Wisconsin 53115 USA • Ph. (262) 728-5551 S515 (Rev. 31/8/00)
  • Page 4 Le seul recours de l’acheteur et la seule responsabilité de Pro-Source est la réparation ou le remplacement des produits défectueux (au choix de Pro-Source). L’acheteur accepte de payer tous les frais de main-d’oeuvre et d’expédition associés à cette garantie et de faire une demande de réparation au titre de la garantie auprès du dépositaire installateur dès qu’un problème est décelé.

Ce manuel est également adapté pour:

Epoxyline aw30hEpoxyline aw42Epoxyline aw42tEpoxyline aw85Epoxyline aw120