Sunbeam SWM6000-CN Manuel page 6

Masquer les pouces Voir aussi pour SWM6000-CN:
Table des Matières

Publicité

TROUBLE
• Unit does not turn on.
• Refill/Reset light
illuminated.
• Mist output minimal to none. * Scale buildup on heating element.
• Water Leaks from tank.
• Crack in Tank.
• Film on tank.
All manuals and user guides at all-guides.com
T R O U B L E S H O O T I N G
TROUBLESHOOTING
PROBABLE CAUSE
* Not plugged in.
* Outlet not functioning.
* Water Tank Empty.
* Unit not reset after refill.
* Scale buildup on heating element.
* Humidifier is not warmed up yet.
* Tank rubber ring is missing.
* Cap not tight enough.
* Tank water is Hot.
* Hot water will cause tank to
pressurize.
* Tanks will crack if hit or dropped.
* Mineral deposits.
SOLUTION
✔ Plug in unit.
✔ Have outlet replaced by a licensed electrician.
✔ Refill Tank.
✔ Follow manual for Reset Instructions.
✔ Remove scale from heating element.
✔ Remove scale from heating element .
✔ Allow 10 minutes for the humidifier to
warm up.
✔ Remove tank cap and replace or reposition
ring.
✔ Tighten the cap.
✔ Fill with cool water only.
✔ Fill with cool water only.
✔ Handle tank with Care.
✔ Clean/disinfect tank as instructed in
weekly cleaning instructions

Publicité

Table des Matières
loading

Table des Matières