F E AT U R E S - O P E R AT I O N S
C L E A N I N G / M A I N T E N A N C E
RESET PROCEDURE
NOTE: When the water in the tank is empty and the water in
the heating chamber is almost empty, the Automatic Shut Off
will activate. The RESET light ( ) will illuminate and the unit
will not operate again until you refill the water tank and
reset the humidifier as outlined below.
1. Turn the power knob to Off ( ).
2. Unplug the unit.
3. Remove and refill the water tank, being sure to follow
the Daily Maintenance instructions. Replace the tank
onto the base.
4.
Allow 15 minutes for the Automatic shut off to reset.
5. After the 15 minutes, plug in the unit and turn the
Power knob to High (2). The Reset light
be off. In about 10 minutes the unit will begin to
produce moisture.
If the reset light
( )
is still on at this point, and the unit
does not begin to produce
then repeat Steps 1-5.
IMPORTANT: If you do not plan to use the humidifier for
two or more days, make sure any residual water is drained
from the water tank and base to prevent algae or bacterial
growth.
Figure 1
D
A
A. HUMIDIFIER TANK
B. HUMIDIFIER HOUSING
C. TANK HANDLE
All manuals and user guides at all-guides.com
( )
should now
moisture within a few minutes,
D. CONTROL KNOB
E. HUMIDIFIER BASE
F. MEDICINE CUP
CLEANING AND MAINTENANCE
INSTRUCTIONS
The following maintenance procedures must be
routinely followed in order to ensure proper,
efficient operation of your humidifier. The unit WILL
NOT WORK CORRECTLY if it is not cleaned properly.
When the unit is in use, daily and weekly maintenance is
recommended. Regular weekly cleaning prevents scale
buildup on the heating element and base. It also prevents
micro-organisms from growing on the base. This ensures that
maximum efficiency will be achieved.
We cannot over-emphasize how essential proper
cleaning is to the maintenance and continued use of
your unit and to the avoidance of algae or bacteria
build-up.
DAILY MAINTENANCE
Allow to cool before maintenance.
1. Before cleaning, set the control to OFF
unplug the unit from the electrical outlet.
2. Remove the water tank then unlock the misting chamber
by rotating the safety lock towards the front of the unit.
Lift mist chamber from the unit's base.
3. Empty water and minerals from the base and place in
the top rack of the dishwasher. This will remove
F
sediment and dirt that has accumulated in the base.
NOTE: It is imperative that the base is cleaned properly. The
C
base is dishwasher safe (top rack ONLY) for easy cleaning.
4. Wipe the heating element clean with a soft cloth after it
has had a chance to cool.
5. Replace misting chamber and engage safety lock. The
Electronic Thermal Control Heating element is lined with
B
a coating that is designed to provide the easiest cleaning
and prolong the operating efficiency of the humidifier.
DO NOT use any metal or hard objects to clean the
E
Heating Element. Never use detergents, gasoline,
kerosene, glass cleaner, furniture polish, paint thinner or
other household solvents to clean any part of the
humidifier.
( )
position and
any