Télécharger Imprimer la page

Xenteq LBC 500 Serie Manuel page 15

Publicité

Les langues disponibles

Les langues disponibles

English
S E T T I N G T H E C H A R G E R
Charge voltages
The LBC 500 has different charging voltages because each battery type needs other
voltages to ensure the longest duration of life. Therefore, the right charging voltages
need to be set beforehand by means of the 'power/mode' button.
The battery may be connected, but is not required.
Connect the charger to the mains. Push directly afterwards, within 5 seconds, on the
'power/mode' button. The green 'Power' LED starts flashing, which means that the
charger is in its setup-mode. By way of pressing the button you can choose between
the 'setting' LED's. Each different LED combination stands for a voltage setting. For
the voltages, see page 44. The schedule below is a directive. Always check if the
recommended charging voltages match with the charging guides of your battery. Most
of all AGM batteries have a large diversity of charge voltages, so for this type of
battery it is even more important that the advised charge voltages are verified.
Never set the charger to your own opinion. This can lead to irreparable damage to the
battery.
Important
The charger can only run the set-up mode after connection with the mains. So when
the charger for instance is reactivated from its stand-by mode, it can't be set.
BATTERY TYPE
START, WET
SEMI-TRACTION, TRACTION
GEL, AGM¹
CALCIUM, AGM², SPIRAL
LiFe-PO4
The charger will leave the setup-mode if the button isn't used for 10 seconds. In this
case the ' power' LED will flash two times. The chosen setting will remain in the
memory of the charger and the setting LED lights when the charger is on.
15
SUGGESTED SETTING
*
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3
4
1 2 3
4
*= factory setting

Publicité

loading

Ce manuel est également adapté pour:

Lbc 512-10s