IMPORTANT–Please Read and Follow!
• Before beginning, please read these instructions completely and carefully.
• Be sure to DISCONNECT THE PLUG of the microwave oven from the electrical outlet before installing the built-in trim kit.
Remove the turntable from the oven cavity.
• Because the kit includes metal parts, caution should be used in handling and installation to avoid the possibility of injury.
• Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
• Please observe all local and national codes and ordinances.
• The installer should leave these instructions with the consumer who should retain for local inspector's use and for
future reference.
• This built-in trim kit is designed for use ONLy wITH VIkING CONVECTION AND CONVENTIONAL MICROwAVE OVENS
SPECIFyING BUILT-IN TRIM kIT VMTk272, VMTk302, VMTk362, VMTk277, VMTk307 or VMTk367 on the rating label on
the bottom face plate of the oven cavity.
• yOUR OVEN CAN BE BUILT INTO A CABINET OR wALL By ITSELF OR ABOVE ANy ELECTRIC wALL OVEN OR wARMING
DRAwER.
Parts Included in VMTK kits
Front Frame Assembly
Front Frame
QTY 1
Bottom Duct Assembly
Cushion QTY 3
QTY 1
27" & 30"Surface Mount
Template 2-sided
or 36"Surface Mount
Back Frame
Template single-sided
QTY 1
Maximum Cutout Opening Width 24-11/16" (627.06 mm)
Minimum Cutout Opening Width 24-3/8" (619.13 mm)
BUILT-IN TRIM KIT TEMPLATE
FOR CUSTOM SERIES MICROWAVE OVEN
Distance between holes A 25-9/16" (649.3 mm)
Distance between centerline to holes 12-13/16" (324.65 mm)
Distance between holes B 28-9/16" (725.5 mm)
Distance between centerline to holes 14-5/16" (362.75 mm)
Floor Line of Cutout Opening
QTY 1
*
Conventional Microwave Built-In Trim Kit
Viking Installation Guide
Duct (A)-1
QTY 1
USE THIS SIDE OF TEMPLATE FOR MODELS
Duct (A)-2
VMTK272 and VMTK302 ONLY.
1. Align the mounting template center line with the center of the cutout
and the floor line with the floor of the cutout. Tape it into place.
2. For VMTK272, predrill 4 holes marked A with a 1/16" drill bit.
For VMTK302, predrill 4 holes marked B with a 1/16" drill bit.
3. Remove template from the cabinet.
Center Line
1-5/32"
(29.6 mm)
TINSKB133MRR0
Custom Series Convection /
QTY 1 *
Duct (A)-3
QTY 1 *
Screw A (1/2" length)
Screw B (1-3/4" length)
QTY 1 *
Duct (B)
QTY 1 *
Screw C (3/4" length)
Duct (C)
*VMTK277, VMTK307 and VMTK367 ONLY.
Greenwood, Mississippi 38930 USA
QTY 1 *
QTY 10 *
QTY 4
QTY 2
111 Front Street

Publicité

Table des Matières
loading

Sommaire des Matières pour Viking VMOC206

  • Page 1 • The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference. • This built-in trim kit is designed for use ONLy wITH VIkING CONVECTION AND CONVENTIONAL MICROwAVE OVENS SPECIFyING BUILT-IN TRIM kIT VMTk272, VMTk302, VMTk362, VMTk277, VMTk307 or VMTk367 on the rating label on the bottom face plate of the oven cavity.
  • Page 2: Basic Specifications

    Basic Specifications Microwave Oven Built-In Custom Trim Kits Description CONVECTION VMOC206 VMTK277 VMTK307 VMTK367 Overall width 24-5/8" (62.5 cm) 26-1/2" (67.3 cm) 29-1/2" (74.9 cm) 35-1/4" (89.5 cm) Overall Height 14-7/8" (37.7 cm) 19-13/16" (50.1 cm) 19-13/16" (50.1 cm) 19-13/16" (50.1 cm) from Bottom Overall Depth 19"...
  • Page 3: Cabinet Or Wall Cutout

    Cabinet or Wall Cutout Exhaust Duct Assembly Provide an opening in the wall or cabinet as indicated in figure . The depth should be a minimum of 20-1/8" DUCT (C) DUCT (B) (51.1 cm). If the Depth (C) dimension is greater than 21" (53.3 cm), the outlet location may be in any area on the rear wall.
  • Page 4: Surface Installation

    Exhaust Duct Assembly Surface Installation SCREW C BOTTOM DUCT ASSEMBLY EXhAuST DuCT ASSEMBLY: Remove the cushions from the adhesive backing. The cushion should be applied to the flanges of the duct assembly as indicated by arrows. See figure 5A. GAP "A" NOTE: CENTER BOTTOM DUCT ASSEMBLy IN THE...
  • Page 5: Flush Mount Installation

    Surface Installation Flush Mount Installation PARTS INCLUDED IN FLUSH MOUNT ACCESSORy kIT (PURCHASED SEPARATELy): • (2) Stainless Steel Scoops • (10) Stainless Machine Screws • (1) Flush Mount Template • (2) Side Trim FOOT * See FLUSH MOUNT TEMPLATE for additional installation instructions. BOT TOM DUCT "...
  • Page 6: Over Oven Installation

    Flush Mount Installation CONVECTION CONVENTIONAL 27" 30" 36" 27" 30" 36" 21-5/16" 21-5/16" 21-5/16" 19-7/8" 19-7/8" 19-7/8" (A) Height (542 cm) (542 cm) (542 cm) (504 cm) (504 cm) (504 cm) 26-15/16" 29-15/16" 35-5/8" 26-15/16" 29-15/16" 35-5/8" (B) width (68.3 cm) (76 cm) (90.4 cm) (68.3 cm)
  • Page 7: Important

    • Ce kit à encastrer est destiné à être utilisé UNIQUEMENT AVEC LES FOURS À MICRO-ONDES TRADITIONNELS ET À CONVECTION VIkING SPÉCIFIANT kIT À ENCASTRER VMTk272, VMTk302, VMTk362, VMTk277, VMTk307 ou VMTk367 sur l'étiquette des spécifications nominales présente sur la plaque frontale inférieure de la cavité du four.
  • Page 8: Spécifications De Base

    Spécifications de Base Four à micro-ondes Kits de garniture à encastrer Descriptión CONVECTION VMOC206 VMTK277 VMTK307 VMTK367 35-1/4 po (89,5 cm) Largeur hors tout 24-5/8 po (62,5 cm) 26-1/2 po (67,3 cm) 29-1/2 po (74,9 cm) Hauteur hors tout 14-7/8 po (37,7 cm) 19-13/16 po (50,1 cm)
  • Page 9: Découpe De L'armoire Ou Du Mur

    Découpe de l’armoire ou du mur Ensemble du conduit d’évacuation Faire une ouverture dans le mur ou l’armoire comme CONDUIT indiqué à schéma . La profondeur doit être au minimum CONDUIT (C) de 20-1/8 po (51,1 cm). Si la profondeur (C) dépasse 21 po (53,3 cm), l'emplacement de la prise peut être situé...
  • Page 10: Installation En Surface

    Ensemble du conduit Installation en surface d’évacuation VIS C ENSEMBLE DU CONDUIT D’ÉVACUATION ASSEMBLAGE Du CONDuIT D'ÉVACuATION : Retirer les coussins du support adhésif. Appliquer les coussins aux brides de l'ensemble conduit comme indiqué par les flèches. Voir schéma 5A. ÉCART "A"...
  • Page 11 Installation en surface VIS (B) VIS (B) VIS (B) VIS (B) POSE DANS L’ARMOIRE : Placer le four près de l’ouverture du mur ou de l’armoire. Brancher le cordon d’alimentation dans la prise électrique. Guider avec précaution le four assemblé dans l’ouverture INSTALLATION Du ChÂSSIS : Placer le CHÂSSIS ARRIÈRE pour qu’il préparée.
  • Page 12: Installation Du Montage Encastré

    Installation du montage encastré Installation PIÈCES INCLUSES DANS LE kIT D'ACCESSOIRES DE INSTALLATION DE LA DÉCORATION : Placer la décoration AVANT sur le CADRE et aligner les pivots à rotule avec les récepteurs. Fixer MONTAGE ENCASTRÉ (ACHETÉ SÉPARÉMENT) : la DÉCORATION sur le CADRE en poussant fermement le cadre avant sur le cadre arrière en engageant les quatre (4) fixations à...
  • Page 13 • Este juego de molduras para empotrado está diseñado para usarlo SÓLO CON HORNOS MICROONDAS DE CONVECCIÓN VIkING y CONVENCIONALES QUE ESPECIFIQUEN EL JUEGO DE MOLDURAS PARA EMPOTRADO VMTk272, VMTk302, VMTk362, VMTk277, VMTk307 o VMTk367 en la etiqueta de potencia en la placa de la parte inferior de la cavidad del horno.
  • Page 14: Especificaciones Básicas

    Especificaciones Básicas Horno Microondas Juego de Molduras para Empotrado Descripción CONVECCIÓN VMOC206 VMTK277 VMTK307 VMTK367 Ancho total 24-5/8" (62,5 cm) 26-1/2" (67,3 cm) 29-1/2" (74,9 cm) 35-1/4" (89,5 cm) Altura total desde la parte 14-7/8" (37,7 cm) 19-13/16" (50,1 cm) 19-13/16" (50,1 cm) 19-13/16" (50,1 cm)
  • Page 15: Abertura Del Gabinete O Pared

    Abertura del gabinete o pared Ensamblaje del ducto de escape Haga una abertura en la pared o en el gabinete como se DUCTO (C) indica en la figura 1. La profundidad debe tener un mínimo DUCTO (B) de 20-1/8" (51.1 cm). Si la dimensión de la profundidad (C) es mayor a 21"...
  • Page 16: Plantilla De Montaje

    Ensamblaje del ducto de escape Instalación en superficie TORNILLO C CONJUNTO DE DUCTO INFERIOR ENSAMBLAJE DEL DuCTO DE ESCAPE: Retire los amortiguadores del adhesivo. Los amortiguadores se deben aplicar a las bridas del ensamblaje del ducto como indican las flechas. Vea la figura 5A. SEPAR ACIÓN "A"...
  • Page 17 Instalación en superficie Instalación del montaje al ras PARTES INCLUIDAS EN EL JUEGO DE ACCESORIO DE MONTAJE (SE COMPRA POR SEPARADO) : • (2) De acero inoxidable bolas • (10) Tornillos inoxidables de máquina • (1) Plantilla para montaje al ras • (2) Molduras laterales BASE * Vea PLANTILLA DE MONTAJE AL RAS para instrucciones adicionales de instalación.
  • Page 18 Instalación del montaje al ras CONVECCIÓN CONVENCIONAL 27" 30" 36" 27" 30" 36" 21-5/16" 21-5/16" 21-5/16" 19-7/8" 19-7/8" 19-7/8" (A) Altura (542 cm) (542 cm) (542 cm) (504 cm) (504 cm) (504 cm) 26-15/16" 29-15/16" 35-5/8" 26-15/16" 29-15/16" 35-5/8" (B) Peso (68,3 cm) (76 cm) (90,4 cm)
  • Page 20 Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 TINSLB016MRR0...

Table des Matières