EOS BI-O-Max Notice De Montage Et D'emploi page 11

Poêle de sauna électrique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Sample bowl differs from
delivered bowl
PLEASE BE SURE TO NOTE!
Do not stack the stones in layers; stack them
loosely instead, leaving as many spaces as
possible to allow the rising hot air to circulate.
Finnish sauna operation
For this type of operation, the vaporizer is not used. It is very
important to make sure that no herbs or essences are
present in the herbal bowl, because these could ignite due
to overheating. Add essences or infusion agents to the
infusion water only according to manufacturer's instructions.
At the end of the sauna session when you are ready for the
infusion, do not pour the water over the stones with the ladle
too quickly. This allows full evaporation of the water and
thereby the full effect of the infusion to be reached.
Operation with vaporizer (only for Bi-O-
Max)
The control of the vaporizer is managed by the control unit.
Either you receive a humidity value which is regulated by a
variance comparison at the sensor or which is determined
through a timing cycle.
Please note that the relative humidity varies greatly due to the
varying temperature distribution in the cabin. The readings
of the hygrometer and the readings at the control unit can for
that reason be very different.
Before the sauna session, check to see whether the water
reservoir is empty. Any remaining water must be drained.
Now fill about 8 ltr. water into the water reservoir. Never add
essences, volatile oils or herbs to the water; instead add
these to the herbal bowl on the lid of the vaporizer.
These volatile oils which are released through action of the
hot, rising steam are automatically distributed throughout
the cabin with the rising steam.
If the water supply in the vaporizer has been drained, a
buzzing signal indicates the water storage. To continue your
sauna session, you have to refill the tank after a 5 minutes
stop of the sauna control or a changing to Finnish sauna for
5 minutes.
The heating rod in the vaporizer must cool down for 5
minutes before cold water is refilled.
Never pour water on the red-hot heating rod. Besides of
the danger of scald, the heating rod could be damaged.
Fill in the water up to the upper water level marking.
All manuals and user guides at all-guides.com
Illust. 6
If additives are put in the water, this generally leads to a
foamy boiling over of the water. In this case the water
must be drained and the interior of the cold reservoir
washed out with a cloth soaked in alcohol or mineral
spirits. Even small remainders of essences on the
vaporizer wall will change the natural molecular structure
of the water.
The drain cock is situated behind the right foot in front of
the oven. Place a suitable bowl under the oven and open
the tap under the show glass.
Caution concerning control units with post-heating
phase. Never leave the herbal bag in the herbal bowl
during the post-heating phase after a moist steam
session. These dry out rapidly in this case and a
present a fire hazard!
De-scaling of the vaporizer (only for Bi-O-Max)
Consult your water utility company to determine the
hardness level of your water. In areas with hardness
level 1 (1-7 German hardness levels), the system
generally works without problems and must be de-
scaled only when necessary.
Should your water lie within the hardness levels 2-4, the
vaporizer must be de-scaled from time to time (in
accordance with the hardness level).
To this end, add the de-scaling product for household
appliances to the water in the vaporizer in accordance
with manufacturer´s instructions. Bring the water-and-
de-scaling product mixture to a boil for about 10 minutes
and allow to cool. After cooling, drain the mixture from
the vaporizer and rinse at least twice with clear water.
Note also the instructions given by the de-scaling product
manufacturer.
Caution concerning control units with post-heating
phase. Never leave the herbal bag in the herbal bowl
during the post-heating phase after a moist steam
session. These dry out rapidly in this case and a
present a fire hazard!
Circuit diagram vaporizer
heating element of vaporizer
2000 W
blk
3 x 1,5 mm²
WS
N
N
WT
Wb
PE
WS = water shortage
WT = water tank
WS N WT
buzzer
J
blk
blk
Illust. 7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Euro-max

Table des Matières