CX-91S 600lb. & 1200lb. Magnetic Locks
INSTA L L AT I O N I NST RU CTI ONS
6. LZ BRACKET FOR IN-SWING DOOR INSTALLATION GUIDE (FIGURE 3)
In-Swinging Door
Fig. 2
Position the L-Bracket close to the doors
upper corner with a gap of 3/8" (10mm).
Make sure the door closes.
Fig. 5
Flat Washer
Rubber Washer
Armature Screw
Armature Plate
Install the armature plate on the
Z-Bracket; using the screw provided.
Fig. 8
Power Supply
Door
Once the Z-Bracket is aligned properly,
install the self-tapping screws to
attach the Z-Bracket to the door.
Opening New Doors to
Innovation, Quality and Support!
Page 4 of 4
Fig. 1
Door
Frame
Fig. 3
Cable Wire
L
Bracket
Fixing
Screw
Allen Wrench
x2
Tighten the maglock on the L-Bracket
using the Allen Wrench.
Fig. 6
Close the door, and position the
Z-Bracket by bringing the armature
plate close to the maglock surface.
Amps 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft 500ft
0.25
0.50
Minimum
Wire Gauge
0.75
(AWG) for
1.00
12VDC
1.50
2.00
Amps 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft 500ft 1000ft
0.25
0.50
Minimum
Wire Gauge
0.75
(AWG) for
1.00
24VDC
1.50
2.00
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
The door frame requires a
minimum height "H" value
H
to accommodate the bracket.
Mag
Lock
H
Door
In-Swinging
12/24 VDC
Fig. 4
Power
Mounting
Bracket
Assemble the Z-Bracket making sure
the Z-Bracket can be adjusted freely,
before tightening.
Fig. 7
Power Supply
Power up the mag lock, allow the armature
plate and mag to engage, and adjust the
position of the Z- Bracket and the door.
DISTANCE IN FEET FROM POWER SUPPLY TO THE FURTHEST LOCK UNIT
18
18
18
18
18
16
18
18
18
16
16
14
18
18
16
14
12
12
18
16
14
14
12
18
14
12
12
16
14
12
18
18
18
18
18
18
18
18
18
18
18
16
18
18
18
18
16
14
14
14
18
18
16
16
18
18
16
14
14
12
16
16
14
14
12
800 LZ
1200 LZ
2-1/16"
2-7/8"
(52mm)
(73mm)
Machine Screw
Door
1000ft
16
14
14
12
12
18
18
16
16
16
16
14
14
12
14
12
12
12
12
File: EISB-EMS-IG (Page 1-2) Ver. A/ 11.03.2020
Camden Part No.: 40-82B176