5. REGULAR INSTALLATION GUIDE (FIGURE 2)
Installation
1
Template
Fold the CX-91S Template along the dotted
line up to 90°.
Note: Installation Template Only for
In-door E.M. Lock.
4
Drill 2 holes on Frame and 3 holes on
door as indicated on the template.
6
Door
This allow the armature plate to pivot
around the armature screw to
compensate for door misalignment.
Cable Wire
9
Cover Screw
Fixing
Screw
PCB
x2
Cover
Anti-Tamper Nut x2
Allen Wrench
Use an Allen key wrench to unscrew
the anti tamper nut and tighten the
fixing screws on the mounting plate.
2
Door
Out Swing
Close the door, position the EM lock
mounting location as close to the
door upper corner with gap 10mm.
5
Armature Screw
Armature Plate
Install the Armature Plate to the door.
Note: Actual installation may varies according to door figures.
7
Rubber
Washer
Mount the FB600 on the door frame
by screw in the self tapping screw on
the holes as indicated on template.
10
** T Handle
Allen Key
3mm
Not
Included
Holding Force
Connect to power supply and test unit.
Door Frame
Template
Sexnut Bolt
Metal Washer
Rubber Washer
Door Frame
EM
Lock
Door
CX-91S 600lb. & 1200lb. Magnetic Locks
INSTA LL AT ION INS T RUCT IONS
3
Door
Place the template against the door &
frame and drill holes according to
template indications.
Wooden Door
Door
8
Once position is correct, screw in others
screws to permanently mount the plate;
and drill the wire cable access hole.
Page 3 of 4