LEDA3001xx-xP/3002xx-xP/3003xx-xP/3005xx-xP
holes in mounting supports, do not change the location of the
connections...
Mechanically moving parts must not show any signs of wear and
tear.
The electric power supply cables must not show any damage.
Have a qualified technician maintain the device.
If the protective glass [3] is damaged, disconnect the lamp
immediately from the mains. Have it repaired immediately by a
qualified technician. Do not use the lamp with a cracked or broken
protective glass.
This luminaire does not have a built-in device to disconnect it from
the electric mains. Make sure to electrically isolate the luminaire
before installation or maintenance activities are performed.
Wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
9.
Technical Specifications
body colour
LEDA300xxx-BP
LEDA300xxx-GP
LEDA300xxx-WP
electrical data
power LED module
LEDA3001xx-xP
LEDA3002xx-xP
LEDA3003xx-xP
LEDA3005xx-xP
total nominal power
LEDA3001xx-xP
LEDA3002xx-xP
LEDA3003xx-xP
LEDA3005xx-xP
nominal voltage driver
nominal voltage LED module
power factor
LEDA3001xx-xP
LEDA3002xx-xP
V. 03 – 16/02/2016
black
grey
white
1 x 10 W COB Epistar
1 x 20 W COB Epistar
1 x 30 W COB Epistar
1 x 50 W COB Epistar
12.5 W
22.5 W
32.5 W
54 W
230 VAC
30-36 V
0.6
0.6
8
©Velleman nv