Usage Of The Water Tank; Charging A Battery - Zipper Maschinen ZI-DS2V-AKKU Mode D'emploi

Pulvérisateur à batterie
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12.2.4 Usage of the water tank

Take the tank cap off by turning it counter-clockwise. Pour water, pesticide or liquid fertilizer into
the tank and close the tank again with the tank cap.
Warning: pesticide or liquid fertilizer must dissolve completely before the mixture is poured into
the tank. Otherwise, the undissolved granules / solids can blog the nozzles. Remove any solids on
the filter after filling.
12.2.5

Charging a battery:

The battery must be fully charged before first use or after prolonged storage.
Insert the charger plug into the charging socket (14) on the gun and connect the charger to a
socket.
The charge indicator LED (15) lights up red. Charging is in
progress.
The machine warms during charging. This is normal. Do not use
pressure sprayer while charging!
Charging is around 2 ~ 2.5 hours. Charging is completed when
the charging indicator light is off.
After charging, unplug the charger and then the charger from the
socket.
Charge the battery only in temperatures between 10 º C - 45 º C.
After prolonged use, let the battery cool before you begin charging.
The supplied charger supplies the lithium battery. Do not use any other charger to charge the
pressure sprayer.
Warning: The lithium battery can be damaged if you use the device during the charging process.
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-DS2V-AKKU
22
Water inlet with
filter net inside
Capacity Scales in Liter
ASSEMBLY
Air valve
Outlet hole
Capacity Scales
in Gallones
1515
1414
22

Publicité

Table des Matières
loading

Table des Matières