Throuble Shooting - IB RUBINETTI DIVE DV310 Notice De Montage

Table des Matières

Publicité

CLEANING
In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and dry them with a soft
towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid detergents which contain corrosive or acidic
substances, abrasive sponges, swab with metallic strings because they could irreversibly compromise the surfaces.
THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE IB RUBINETTE-
RIE FROM ANY WARRANTY OBLIGATION.

THROUBLE SHOOTING

ERROR
The shower does not light up, no light
on the controls
Flow of intermittent, unstable and
noisy water
Water temperature changes
Only hot water
The DIVE control light fl ashes
All manuals and user guides at all-guides.com
POSSIBLE PROBLEM
No power to the control unit
No power to the commands
Presence of air inside the system
The inlet valves do not open comple-
tely
Debris in the fi lters
Unbalanced supply pressure
Unbalanced supply pressure
The boiler can not provide adequate
hot water
Incorrect connection of hot and cold
water inlets
Failure of the temperature sensor
SOLUTION
Check that the LED on the DIVE
control unit is switched on. If it is
not check that the power supply is
properly connected
If the LED on the DIVE control unit
is on, check that the data cable is
properly connected
Keep the showerhead low to allow
the air to go out
Check and open all valves
Clean the fi lters if necessary
Check that the system is properly
installed and that there are no other
water requirements
Check that the system is properly
installed and that there are no other
water requirements
Mount a fl ow regulator at the hot
water inlet
Check the hot and cold connections
and correct them if necessary
Replace the DIVE control unit