Installation And Operating Instructions; Electrical Connection - Dimplex EF 12/20 Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
EN

Installation and Operating Instructions

EF12/20, EF 12/20 TI, EF 12/20 TID, EF 12/10
1. Important Information
Keep these instructions in a safe place and pass them on to
possible future owners.
• The device is only suitable for room heating within enclosed
rooms.
• Repairs and corrective measures may only be carried out by
a qualified technician.
• Disconnect the power supply in the event of a fault (pull out
the device plug or switch off the fuse).
• Do not cover the heater with any objects; fire
hazard!
The device carries the symbol shown on the right,
which indicates that the heater must under no
circumstances be covered with any objects.
• Observe the minimum clearances.
• Caution! The outer surfaces of the device, and in particular
the air outlet grid, become hot during operation.
• Children or persons who are not capable of operating the
device safely must not operate the heater. Ensure that
children do not play with the device.
• Caution! Potential dangers can arise when the device
switches on automatically, e.g. devices which have been
covered or blocked by objects since they were last used can
cause fire.
• Do not operate the heater in rooms where highly
inflammable substances are used (e.g. solvents, etc.).
• Connecting lead must not be laid over the device.
2. Technical data
Heat output:
EF 12/20, TI, TID: 2000 W
EF 12/10: 1000 W
Supply voltage:
1/N/PE~, 230 V, 50 Hz
Degree of protection:
IP24, IP20 (EF 12/20 TID)
Safety class:
I (with protective conductor)
Dimensions:
(W x H x D) 300 x 405 x 120 mm
Weight:
3,25 kg
3. Installation
The heater must only be installed and operated on a vertical
wall as shown.
Installation below a wall socket is not permissible.
The device plug must be accessible after installation.
Install the device in such a manner that the controls cannot be
touched by a person in the bathtub or under the shower.
In addition, a minimum clearance of 750 mm between
inflammable objects e.g. curtains, towels or heat-sensitive
plastics, and the front of the unit must be maintained.
The device is mounted to the wall with 3 screws. The enclosed
plastic bag contains screws and dowels.
All manuals and user guides at all-guides.com
Observe the minimum clearances! Dimensions in mm.
Mounting Instruction
- Unlock the wall bracket (A) and remove from the device.
- Drill mounting holes for the wall bracket and insert the
- Align the wall bracket and firmly screw it onto the wall.
- Hang the device on the wall mount.
- Pivot down the heater and push into place (B).

4. Electrical Connection

The voltage marked on the type plate must correspond to the
supply voltage (A.C supply only).
When the power line of this device is damaged, it must be
replaced by the manufacturer or after-sales service, or by a
similarly qualified person, in order to avoid risks.
Due to inadvertant resetting of the thermal cut-out, this
appliance must not be supplied through an external switching
device.
4
250
300
dowels.
B
280
405
250
308
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ef 12/20 tiEf 12/20 tidEf 12/10

Table des Matières