BEFORE STARTING

The MINI-PRO DD PUMPS are dosing systems controlled by a microprocessor with a display. They represent the jewel in
the crown of dosing systems and combine easy installation with a wide range of features,
MINI-PRO DD PUMPS were designed for all types of single-tank or conveyor dishwashers.
In the case of "timed" dosing, injection will take place when the signal is detected and will last the programmed
period of time, with the pump dosing at the set speed.
In the case of volumetric dosing, injection will take place when the signal is detected and will last as long as the
signal is present, with the pump dosing at the programmed speed.
- All settings are programmed using the keyboard on the front of the peristaltic pump.
Please read this manual carefully, paying particular attention to the warnings and cautions related to the
installation procedures. Always apply the necessary safety procedures, including the use of adequate personal
protective equipment for your face, eyes, hands and clothing.
:
 Check the package's contents, the technical characteristics and the operating principle.
 Carry out hydraulic, mechanical and electrical connections.
 Program the setting parameters.
1
INSPECTIONS
1.1
POINTS TO CHECK BEFORE INSTALLATION:
- Make sure all materials are provided.
- Make sure that the machine is compatible with the device's characteristics (voltage, pressure).
1.2
CONTENTS OF THE PACKAGE
Before starting work, make sure that the package contains the following:

Box complete with peristaltic pump

Foot filter

Detergent injector

Suction and delivery hoses

Fixing bracket with screws and wall plugs (1)
1.3

TECHNICAL CHARACTERISTICS


Power Supply: 100 - 240 VAC 50-60 Hz (24 VAC 50-60 Hz on demand)

Consumption: 5 W

Fuses: 400mA 250 VAC

Fuses: 1 A 250 Vac (for the version 24 Vac)

Detergent pump flow rate: 0,7...7 l/h or 1...10 l/h at 0,1 bar - 0,4...4,1 oz/min or 0,7...6 oz/min at 1,5 psi

Rinse aid pump flow rate: 0.1. ... 1 l/h at 3 bar - 0,1. ... 0,7 oz/min at 45 psi