Electrical Connection - Areglio PRG383 Mode D'emploi

Programmateur electronique monophasé-triphasé pour commande de portes motorisees
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Electrical connection

Before connecting the appliance make sure that the voltage and frequency rated on the data plate
conform to those of he mains supply.
THREEPHASE/SINGLEPHASE MAIN SWITCH:
Connect the power cables directly to the door security switch
2/4/6 Threephase power supply 400V3~
Singlephase power supply 230V~
4/6
Important! Before switching on the power to the appliance make sure that the 230V~/400V3~
transformer power jumper "S1" (fig.4 page.2) is in the correct position. This jumper regulates the
power supply to the transformer according to the mains supply. A jumper must be inserted between
binding posts "A" and "B" if you have a power supply of 400V3~ and a jumper must be inserted
between binding posts "B" and "C" if you have a power supply of 230V~
TERMINAL BOARD CONNECTIONS
1
Earth binding post (mains supply)
2
Motor earthing wire (output)
3-4-5 Three phase/ single phase motor output Opening- Closing- Common
6-7
Electronic braking device positive/negative 24Vdc output
8-9
24Vac 10W flashing warning lamps indicating gate in movement
9-10 24Vac 3W output. Indicates that the gate/door is open.
11-12 24Vac 10W output, powering external devices (Photoelectric cells, etc.)
13
FTCI (contact N.C.) Safety and control devices input (photo-cells invert the travel direction when
an obstruction is detected) .
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
14
FTCS (contact N.C.) Safety and control devices in input
(photoelectric cells stopping the gate when an obstruction is detected) The opening of this contact
will block all movement, during opening and closing, until the obstruction has been removed, due
to the safety device cutting in, the gate will then continue moving until it reaches a travel limit.
15
Common for all inputs and outputs (negative)
TD (contact N.O.) Dynamic button input (Open-Close, selected via Dip-switch)
16
17
Radio receiver antenna pole
18
Mass for radio receiver antenna
FCA opening travel limit input (contact N.C.)
19
FCC closing travel limit input (contact N.C.)
20
21
Common for all inputs and outputs (negative)
TA (contact N.O.) Opening button input
22
TC (contact N.O.) Closing button input
23
TB (contact N.C.) Blocking button input.
24
TAL Limited opening button. If the automatic re-closing function is inserted the closing movement
25
will be activated after the pause time has expired.
26-27 BSP Passive safety input (N.C.)
If this contact is open the power supply to the controls (including the electronic card) will be inter-
rupted. Insert a normally closed contact which is able to support a load of 30Vdc 100mA. This
safety device should be installed in addition to the normal active safety devices (Caution! This input
cannot be connected in series with the FTCI, FTCS, TB as they do not share the same common).
It could also be wired in series to a fixed position anti-crush buffer or be used an emergency device
in line with the local standards and regulations in force.
N.B.: ALL UNUSED NC CONTACTS MUST BE JUMPED
17
18
19
20
21
22
23
24
25 26
NO
NO
NC
NO
6
7
8
9
11
12
13
14
10
+
-
(fig. 2-3 pag. 2)
27
15
16
1
2
3
NO
10
4
5
M
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zvl364.02

Table des Matières