INSTALLATION INSTRUCTIONS
REQUIRED GROUNDING METHOD:
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized
parallel blades) It must be plugged into a mating grounding-type receptacle, connected to a correctly polarized
120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of
the installer or user to have the existing receptacle changed to a properly grounded and polarized receptacle in
accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes
and ordinances, the receptacle replacement shall be in accordance with the National Electrical Code. THE THIRD
GROUND PRONG SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. The electrical supply must be
a 120 volt, 60 Hz single phase, 15 AMP circuit. The power receptacle must be a NEMA 5-15R device to accept the
three prong plug supplied with the unit.
All manuals and user guides at all-guides.com
THIRD GROUND PRONG
13
US
CA