The OZONOS AC-1 PLUS and AC-1 PRO are not
designed for 24/7 use where people are always in
the same room. We recommend not staying more
than 8 consecutive hours in the room in which
the device is in operation. The OZONOS AC-1
PLUS and AC-1 PRO are particularly suitable for
professional use and for faster, more intensive
cleaning.
6. LIFESPAN OF THE UV-C BULB
The lifespan of the UV-C bulb (C) is 8,000 opera-
ting hours. After 8,000 operating hours have been
reached, the status lamp lights up yellow/orange.
The bulb must then be replaced in order to ensure
the device's continued effectiveness. If performance
drops before the bulb has reached around 8,000
operating hours or 36 months, it must be checked
for dust or other contamination. To do this, please
follow the instructions in point 7.1 or send the device
to OZONOS GmbH for inspection.
7. MAINTENANCE
Device maintenance must be carried out by a
qualified electrician.
7.1. Cleaning the housing and the UV-C bulb
The OZONOS Aircleaner should be kept dirt- and
dust-free.
Remove the plug from the mains socket before
carrying out any work on the housing or the UV-C
bulb.
WARNING
This device contains a UV emitter.
Do not look directly at the light source.
11.10.19 | AIRCLEANER AC-I / AC-1 PLUS / AC-1 PRO | OPERATION & MAINTENANCE INSTRUCTIONS
UV-C radiation
Before the housing of the OZONOS Aircleaner
is opened, the device must be switched off and
the plug removed from the power supply.
There is the risk of optical radiation from UV
rays if the housing is opened while the device is
in operation. This can lead to extremely painful
conjunctivitis and skin irritation!
Cleaning the housing
Please do not clean the OZONOS Aircleaner wet
(it is best to use a slightly damp microfibre cloth).
Do not use any chemical cleaning agents.
Cleaning the UV-C bulb
The UV-C bulb inside the OZONOS Aircleaner should
be cleaned as needed – after around 36 months of
normal operation. To do this, follow these steps:
1. Switch off the OZONOS Aircleaner using the switch (B);
the blue indicator light goes out. Unplug the mains plug.
2. Open the housing on the bottom by loosening the two
fixing screws using a size 10 Torx key and lift the cover off.
3. Using the Torx key, open the cover above the UV-C bulp.
4. Disconnect the connector from the UV-C bulb (C).
5. Remove the UV-C bulb from the two clip brackets.
6. Use a dry, soft, fine brush to remove dust from the bulb.
7. Use a brush to clean the fan.
8. Put the cleaned UV-C bulb back into the clip brackets.
Then replace the cover and secure it with the screws.
9. The OZONOS Aircleaner is now ready for use again.
7.2. Changing the UV-C bulb
1. Switch off the OZONOS Aircleaner using the
switch (B); the indicator light goes out. Unplug the
mains plug.
ENGLISH | 13