12 | ENGLISH
4. CONSTRUCTION
A Housing | B On/Off switch with blue indicator light | C UV-C special bulb | D Fan
C
B
5. OPERATION
5.1. Placement
Place the device on a fi rm surface approx. 2 metres
above the fl oor (if possible on something such as a
shelf or cabinet) to allow for optimal air circulation.
Warm, stuff y air rises. For maximum eff ect the device
should not be placed near an exhaust fan. Note that
the minimum room size should be 55 m³.
5.2. Commissioning and operation
1. Connect the OZONOS Aircleaner to an earthed 230-
volt mains connection.
2. Press the switch (B) to turn on the air purifi er. The
indicator light on the switch lights up. The status
light of the UV-C bulb (C) glows blue. After
8,000 operating hours the lamp must be chan-
ged, the status lamp now lights yellow/orange.
A
D
11.10.19 | AIRCLEANER AC-I / AC-1 PLUS / AC-1 PRO | OPERATION & MAINTENANCE INSTRUCTIONS
3. It emits a gentle hum.
4. The device may heat up during operation.
5. To switch off , press the switch (B), the indicator
light turns off .
5.3. Treatment duration
The OZONOS Aircleaner is designed for long-term
indoor use. The optimum use of the OZONOS Airc-
leaner depends on the type of application, the type
and degree of internal air contamination, and the
room size. Depending on the level of contamination,
two to four hours of treatment time is suffi cient to
remove odours in a 55 m
recommend uninterrupted use for people prone to
allergic and asthmatic reactions.
Produced in accordance
with ISO 9001: 2015
3
2
/ approx. 25 m
room. We