Depending on the model, the gas control block is positioned either:
behind a stainless steel door on the underside of the appliance
mounted in the middle of the floor plate of the appliance
behind the frame (accessible by tilting the frame upwards)
These appliances are fitted with a manual GV36 gas control (see fig.2.1) that optionally
can be adjusted with a G30 remote control.
The pilot light always has to be lit before the main burner can be used. Rotary knob A
functions as a main valve and has to be used to lit the pilot light. Use rotary knob B to
adjust the height of the flames.
Warning! When the pilot extinguishes, for whatever reason, you should wait at least 5
minutes before trying again. Possible causes of pilot extinguish are:
operation error
interference of the safety device
failure in the pilot flame system
Contact a qualified installer when the appliance extinguishes regularly.
2.2.1 Pilot ignition
To ignite the pilot light:
simultaneously press and turn rotary knob A anti-clockwise to the
position at the
element starts to ignite
hold the knob in this position for some seconds to clear the air from the pipe and
allow gas to reach the pilot burner
if the pilot light does not light return to the
hold the knob for about ten seconds after the pilot light ignites
turn the knob anti clockwise to the
burner to be ignited (see main burner ignition)
2.2.2 Pilot extinguish
To extinguish the pilot light:
first turn rotary knob B clockwise till the
turn rotary knob A clockwise to the
simultaneously press and turn rotary knob A clockwise to the
(spark) position a click will be heard and the piezo-electric
(large flame) position to allow the main
(small flame) position
(stop) position and restart
(off) position
(off) position
UK
IRL
(small flame)