Error codes are defined:
ERROR CODE
0
No fault
1
Current anomaly or MOS tube damage
2
Grip shifter anomaly (boot detection)
3
Motor phase failure
4
Abnormal motor Hall signal
5
Brake abnormal (boot detection)
6
Under voltage
7
Motor stop protection
8
Controller communication anomaly
9
Display communication anomaly
Only when the fault is excluded, the fault display interface can exit.
5.19
SET OPERATION:
Press the set key for 3 seconds to enter the set interface in the normal boot mode, and the set icon is in the
state of 1Hz flash.
Press the set button to switch from 0 to 4 cycle settings interfaces, long press the set key to exit the setup
interface.
In the current settings, press the key "+" or "-" to select the desired Parameter configuration. Long press
the SET key 1 second to save and exit.
5.20
DISTANCE INDICATOR.
Total distance (ODO): Total (Km) mileage recording from first riding to the current (Km) mileage, this
parameter in the conventional interface can be cleared by press "+" and "-" in 12s.
Trip distance: Single (Km) mileage, can be cleared by pressing "-" key in SET 1.( More than 500km
automatically cleared).
5.21
TRIP TIME INDICATOR: This parameter is automatically cleared after shutdown.
DEFINITION
82/89