INSTALLATION DIMENSION:
• MODEL 8410755
• CAPACITY: 15GPM
• MAX PRESSURE: 3600PSI
2-SPOOL DIRECTIONAL
CONTROL VALVE FLOAT-PUSH
INSTRUCTION MANUAL
Float Position
Spring return
to neutral
FEATURES:
• Spool action: 1st spool: 4-position 4-way, float position at 4th position
2nd spool: 3-position, 4-way/spring return to neutral from either
working position
• Open centre
• Max.return line pressure:1,100psi
• Relief valve pre-set@2,100psi, adjustable from 1,500psi to 3,750psi
• Max. continuous pressure: 3,600psi
• Max. peak pressure: 4,700psi
• Max. continuous flow: 15GPM
• Peak flow: 16.5GPM
• Port: T2 Port is SAE#10 others SAE#8
ADJUSTABLE RELIEFS – An adjustable relief valve is standard on
all mono-block directional valves. The standard factory setting is
2, 100PSI. Other setting can be specified.
WARNING
All hydraulic valve must be properly installed into the hydraulic system to prevent personal injury and/or
property damage. Further, the improper servicing of a valve may result in personal injury and/or property
damage. Please read and understand all catalog and service information before starting, as with all mechanical
work the proper tools, knowledge, and safety equipment are required, always wear safety glasses.
Make sure all pressure has been relieved in the hydraulic lines before installing or servicing a hydraulic
valve.
Escaping hydraulic fluid under pressure can have sufficient force to penetrate skin, causing serious
personal injury. Do not use your hand to check for hydraulic leaks.
Before installing or servicing a hydraulic component make sure all weight has been removed from the
cylinders or motors before disconnecting hydraulic lines.
Disconnecting the hydraulic lines while the cylinder or motor is under load may result in the unexpected
rapid movement of machine resulting in serious personal injury.
Do not exceed the operating specifications for pressure, flow or temperature, all hydraulic systems
require a means to limit the maximum pressure. This requires either a pressure relief valve in the system or a
pump that has pressure compensation.
Overpressure may cause sudden and unexpected failure of a component in the hydraulic system
resulting in serious personal injury, always use a gauge when adjusting a relief valve.