Télécharger Imprimer la page
Amana ADB1400PY Mode D'emploi
Amana ADB1400PY Mode D'emploi

Amana ADB1400PY Mode D'emploi

Lave-vaisselle sous comptoir

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

PRODUCT MODEL
NUMBERS
ADB1400PY
ADB1300AF
ADB1500AD
ADB1100AW
Electrical Requirements: 120 V, 60 Hz, AC only, 15 A or 20 A. Fused electrical
supply. Copper wire only. A time-delay fuse or circuit breaker and separate
circuit is recommended.
If direct wiring dishwasher: Use flexible,
armored, or nonmetallic sheathed copper wire
with grounding wire that meets the wiring
requirements for your home and local codes and
ordinances. Use a UL Listed or CSA Approved conduit connector.
If connecting dishwasher with a power supply cord:
Use power supply cord kit (Part Number 4317824)
marked for use with dishwashers. Follow the kit
instructions for installing the power supply cord.
Power supply cord must plug into a grounded 3 prong outlet
located in the cabinet next to the dishwasher opening. Outlet must
meet all local codes and ordinances.
Water Supply Requirements: A hot water line with 20 psi to 120 psi
(138 kPa to 862 kPa) water pressure. Water temperature must be 120°F (49°C)
water at dishwasher. Use 3/8" (9.5 cm) O.D. copper tubing with compression
fitting or flexible braided water supply line.
NOTE: 1/2" (1.3 cm) minimum plastic tubing is not recommended.
Use a 90° elbow with 3/4" (9.5 cm) hose connection with rubber washer. (part
number W10273460). Do not solder within 6" (15.2 cm) from water inlet valve.
Drain Requirements: A new drain hose is supplied with your dishwasher. If
this is not long enough, use a new drain hose with a maximum length of 12'
(3.7 m) (Part No. 3385556) that meets all current AHAM/IAPMO test standards,
is resistant to heat and detergent, and fits the 1" (2.5 cm) drain connector of
the dishwasher.
Make sure to connect drain hose to waste tee or disposer inlet above drain trap
Air gap
Use 1/2" (1.3 cm) minimum I.D. drain line fittings.
If required, the air gap should be installed in accordance with the air gap
installation instructions. When connecting the air gap a rubber hose (not
provided) will be needed to connect to the waste tee or disposer inlet.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without
notice.
W11542836B
ADB1400AG
ADB1500AM
ADB1400AM
in house plumbing and
20" (50.8 cm) minimum above the
floor. It is recommended that the drain
hose either be looped up and securely
fastened to the underside of the
counter, or be connected to an air gap.
Make sure to use an air gap if the drain
hose is connected to house plumbing
lower than 20" (50.8 cm) above
subfloor or floor.
Undercounter Dishwasher
PRODUCT DIMENSIONS
33
/
"
1
2
(85.1 cm)
minimum
with rear
leveling
legs
removed
*Insulation may be compressed
(not used on all models)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
1

Publicité

loading

Sommaire des Matières pour Amana ADB1400PY

  • Page 1 Undercounter Dishwasher PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS ADB1400PY ADB1300AF ADB1400AG ADB1500AM ADB1500AD ADB1100AW ADB1400AM Electrical Requirements: 120 V, 60 Hz, AC only, 15 A or 20 A. Fused electrical supply. Copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.
  • Page 2: Cabinet Cutout Dimensions

    CABINET CUTOUT DIMENSIONS NOTE: Shaded areas of cabinet walls show where utility connections may be installed. **Measure from the lowest point on the underside of the countertop. May be reduced to 33¹/ " (85.1 cm) by removing the rear leveling legs from dishwasher.
  • Page 3: Lave-Vaisselle Sous Comptoir

    Lave-vaisselle sous comptoir NUMÉROS DE MODÈLE DU PRODUIT DIMENSIONS DU PRODUIT ADB1400PY ADB1300AF ADB1400AG ADB1500AM ADB1500AD ADB1100AW ADB1400AM Spécifications électriques : Alimentation de 120 V CA à 60 Hz et protégée par un fusible de 15 A ou 20 A. Conducteurs de cuivre uniquement. On recommande d’utiliser un fusible ou un disjoncteur temporisé...
  • Page 4 DIMENSION DE L’OUVERTURE À DÉCOUPER DANS L’ARMOIRE REMARQUE : Les zones grisées des parois de l’armoire indiquent les endroits où les raccordements électriques peuvent être installés. **Mesurer depuis le point le plus bas de la face inférieure du comptoir. Cette dimension peut être réduite à 33 ¹/ po (85,1 cm) en retirant les pieds de nivellement arrière du lave-vaisselle.
  • Page 5: Dimensiones Del Producto

    Lavavajillas para instalarse debajo del mostrador NÚMEROS DE MODELOS DE PRODUCTOS DIMENSIONES DEL PRODUCTO ADB1400PY ADB1300AF ADB1400AG ADB1500AM ADB1500AD ADB1100AW ADB1400AM Requisitos eléctricos: Un suministro eléctrico de 120 V, 60 Hz, CA solamente, con fusibles de 15 A o 20 A. Solo cable de cobre. Se recomiendan un fusible retardador o un cortacircuitos y un circuito separado.
  • Page 6 DIMENSIONES DEL CORTE DEL ARMARIO NOTA: Las áreas sombreadas de las paredes del gabinete muestran dónde se pueden instalar las conexiones de servicio. **Medido desde el punto más bajo del lado inferior del mostrador. Se puede reducir a 33¹/ " (85,1 cm), quitando las patas niveladoras traseras del lavavajillas. **Mínimo, medido desde el punto más angosto de la abertura.

Ce manuel est également adapté pour:

Adb1500adAdb1300afAdb1100awAdb1400agAdb1400amAdb1500am