CHECKING FOR LEAKS
Warning: Before using this outdoor fireplace, make sure you have read, understand and
are following all information provided in the "Important safeguards" sections. Failure to
follow those instructions can cause death, serious bodily injury or damage to property.
BURNER CONNECTIONS
1. Make sure the regulator hose and valve connections are securely fastened to the burner and the tank.
2. Visually check the connection between the burner/ venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
4. Please refer to diagram for proper installation (figure1and 2).
5. If the burner/veturi tube does not rest flush to the oriflce as shown (figure1and 2), please contact
1-866-905-4107 for assistance.
Warning: Failure to inspect this connection or follow these instructions could cause a fire
or an explosion which can cause death. se
TANK/GAS LINE CONNECTION OR LEAK TEST
1. Make 2-3 oz of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the
3. Connect LP gas tank per "Installing LP Gas Tank" section.
4. Turn off the igniter cover and put the battery inside according t o the electrode (Figure 4).
5. Close the firepit door panel.
6. Turn LP gas tank valve to "OPEN".
7. Spoon several drops of solution , or use a squirt bottle, at all "
a. If any bubbles appear, turn LP gas tank valve to "CLOSED", reconnect and re-test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve to "CLOSED" and disconnect
LP gas tank, per "Disconnecting LP Gas Tank". Contact 1-866- 905-4107 for assistance.
c. If no bubbles appear after one minute, turn LP gas tank valve to "CLOSED", wipe away solution and proceed.
Figure 1
Questions, problems, missing parts? Before returning to your retailer, call our customer service department
at (866) 905-4107, 8:30 a.m. – 5:00 p.m. PST /11:30 a.m.- 8:00 p.m., EST, Monday- Friday.
Fire Pit Operation
Vendor stock No. FHTS80030
r ious bodily injury or damage to property.
position (Figure 3).
"
OFF"
Figure 2
" locations (Figure 1 and 2).
X
Figure 3
23
! "