en
5. Operation
3 For safe operation of the pump, sufficient space and a safe stand must be available.
NOTICE
Do not force the speed controller, otherwise it may be damaged. Then the motor will no longer work
properly.
!
WARNING
Danger of injury on the fingers due to free running drive shaft!
Before disconnecting or connecting the pump tube, necessarily switch off the motor and remove the battery.
► To start the motor, press the on/off switch (→ Fig. 7). After a long break, press the On/Off switch twice
to exit sleep mode. During failure-free operation, the on/off switch lights up continuously.
► The flow rate can be increased (clockwise) or decreased (counterclockwise) by turning the speed con-
troller (→ Fig. 7).
► To turn off the motor, press the on/off switch again. The speed controller does not have to be turned
back. The motor starts at the last set speed.
► Remove the battery after each use of the motor and place it on the battery charger.
Sleep mode
► After 2 minutes downtime, the motor switches to sleep mode. Then the first actuation of the on/off
switch causes the change back to the operating mode. Press the on/off switch again to start the motor.
Battery discharged
► The on/off switch starts to flash when the battery is discharged. This condition cannot be stopped. The
battery must then be charged with the battery charger (→ Operating instructions battery charger).
Overload
► The motor automatically switches-off when overloaded. The on/off switch starts to flash. The error must
be acknowledged by pressing the on/off switch again. If necessary, reduce motor speed. If the overload
persists, check the cause → Troubleshooting.
Disconnect pump tube from motor:
► Switch off the motor and wait until the engine stops turning.
► Remove battery.
► Open quick fastener (→ Fig. 3).
► Disconnect pump tube from motor.
14