Cleaning

8.
The ionizing needle (emitter) must be cleaned at least every 14 days using a dry
lint free cloth
Caution!
Risk of personal injury. The ionizing needle is pointed and sharp!
When cleaning the IONSTAR, the device must be disconnected from the
compressed air supply

Troubleshooting

9.
problem
No ionization
LED blinks off and on
spark discharge (arc-over)
Please note:
In case a fault or malfunction occurs, which cannot be rectified using
the measures described above, please contact us at:
Herrmann Lack-Technik GmbH
Bahnhofstr. 32
D-93483 Pösing
Gemany
All manuals and user guides at all-guides.com
cause
The ionization device is
soiled
Incoming air pressure is too
low
The ionization device is
soiled with conductive
particles, materials or fluids
The ionizing needle
(emitter) is too close to a
conductive material
The ionization device is
damaged
Seite 19 von 30
action necessary
Clean the IONSTAR
thoroughly
Check the incoming air
pressure is within required
range on minimum 3 to
maximum 5 bar
Make sure to press the
lever completely
Clean the IONSTAR
thoroughly
Increase the distance of the
IONSTAR to the electrically
conductive material which
is causing the problem
Take the device out of
service immediately