18 | English
A socket outlet with earthing contact 7 is inte-
grated in the vacuum cleaner, which allows for
connection of an external power tool. The vacu-
um cleaner is automatically put into operation
via the power tool. Observe the maximal allowa-
ble load of the connected power tool.
For connecting power tools, various hose sys-
tems are available as accessories.
Set the Airflow regulator 5 to the hose diameter
being used (19 mm or 35 mm).
To ensure sufficient dust transport at the vacu-
um location, the minimum airflow for the power
tool connected may not be fallen below.
Hose Diameter
35 mm
19 mm
Set the mode selector switch 6 to the operation
with remote automatic switching symbol.
In this operating mode, the airflow is electroni-
cally monitored according to the setting of the
Airflow regulator 5. Sufficient dust transport is
ensured when the setting is correctly selected.
To start the operation of the vac, switch on the
power tool connected to the socket 7. The vac-
uum cleaner starts automatically.
When the warning light 4 flashes and the alarm
sounds, the vacuum cleaner must be checked as
described under "Malfunctions".
To switch off the vac, switch off the power tool.
The vacuum cleaner switches off automatically
approx. 6 seconds later.
In the operating mode ENT with remote auto-
matic switching, the electronic reduced starting
current limits the power consumption when
switching on the vacuum cleaner, and thus al-
lows operation from a 16-A circuit breaker.
1 609 929 K11 | (18.2.09)
All manuals and user guides at all-guides.com
Electromagnetic filter cleaning
The machine is equipped with an electromag-
netic filter cleaning system, which removes dust
adhering to the folded filter 18.
The filter cleaning system must be actuated lat-
est when the vacuuming performance is no long-
er sufficient.
Set the mode selector switch 6 to the symbol
electromagnetic filter cleaning. A possibly con-
nected power tool must be switched off.
The machine vibrates for approx. 10 seconds
and switches off automatically.
Wait shortly before restarting the vacuuming op-
Airflow Setting
eration so that the dust can settle in the contain-
3
70 m
/h
er.
3
The filter cleaning frequency depends on the
20 m
/h
type and amount of dust. With regular usage,
the maximum vacuuming performance is main-
tained longer.
Wet Vacuuming
Note: Before wet vacuuming, the dust bag 17
must be removed and the container 11 must be
emptied.
The machine is equipped with level sensors 20.
The vac switches off when the maximum filling
height is reached. Set the mode selector switch
6 to off.
After vacuuming, remove the folded filter 18 in
order to avoid mildew, and allow it to dry thor-
oughly, or remove the vacuum lid 3 and allow it
to dry.
Do not vacuum inflammable or explosive
fluids; for example, benzene, oil, alcohol,
solvents. Do not vacuum hot or burning
dust. Do not operate the machine in rooms
where the danger of an explosion exists.
The dusts, vapours or fluids can ignite or ex-
plode.
The vacuum cleaner may not be used as a
water pump. The vacuum cleaner is intended
for vacuuming air and water mixtures.
Before any work on the vacuum cleaner it-
self, pull the mains plug.
Bosch Power Tools