H-5501
HEAVY DUTY 5 CHANNEL
CABLE PROTECTOR
COMPONENTS
End Cap
36" Lineal Protector
ASSEMBLY
Interlock with dog-bone connectors to extend
protection length. (See Figure 1)
Figure 1
• Inspect areas for safety hazards.
• Assemble sections by aligning female connectors
over male connectors and press with foot to secure.
• Open cover and install cables down into channels.
• Close cover flush with base.
• Test installation for intended use.
• Periodically inspect installation.
PAGE 1 OF 6
1-800-295-5510
uline.com
INSTRUCTIONS
CHANNEL CAPACITY
4 Outer Channels
Center Channel
LOAD CAPACITY
End Cap
The heavy duty 5 channel cable protector has different
load supporting capabilities depending on type of
vehicle and temperature. The load capacity decreases
in warm environments. Test before use and inspect
periodically. Suitability must be verified by testing under
actual conditions.
MODEL
NO.
H-5501
OPERATING TEMPERATURE
-40° to 120°F (-40° to 48°C)
CHEMICAL RESISTANCE
Tested for compatibility with common motor oils,
gasoline and diesel fuel. Limited resistance to brake
fluids and other chemicals.
MATERIAL
UV-stabilized polyurethane elastomer.
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
CHANNEL CAPACITY - MAXIMUM DIAMETER
1.375" width x 1" height
1.65" width x 1" height
LOAD CAPACITY PER TIRE
MAX LOAD 70°F (21°C)
16,300 lbs.
LOAD CAPACITY PER AXLE
MAX LOAD 70°F (21°C)
32,600 lbs.
0421 IH-5501